4. OPERATING INSTRUCTIONS 

4.1. MEASUREMENT DESCRIPTION 

1.  Press the power key 

 to turn on the meter 

2. Press the 

 key to select W/m

2

 or BTU/(ft

2

*h) measurement 

3.  Remove the protection cap of the photo detector and expose it to the light source in 

horizontal position. Read the sunlight value on the LCD display 

4.  Wait for values to be stable on the display. Press “D-H” key to activate the DATA 

HOLD function blocking the result on the display 

 

 

CAUTION 

 

If the instrument displays "OL", the input signal is too strong. A higher range 
must be selected. 

 
5.  When the measurement is completed, fit the photo detector cap and check that the 

indication value should be “000” regardless of the range. If no, adjust the “ADJ” trimmer 
on “000” before pressing the power key to turn off the meter 

 
 

5. PREVENTIVE MAINTENANCE 

5.1. GENERAL INFORMATION 

This is a precision instrument. To guarantee its performances be sure to use it according to 
these instructions and keep it stored on suitable environmental conditions Do not expose it to 
high temperatures or humidity. Be sure to turn it off after use. If you expect not to use the 
instrument for a long period remove batteries to avoid leakages of battery liquid which 
could damage the its inner components. 
 

5.2. BATTERY REPLACEMENT 

When the low battery indication “

” is displayed, replace the battery. 

1.  Switch off the instrument 
2.  Press the battery cover and push in the direction of the arrow to open 
3.  Replace the battery with a new one of the same type (9V 6LR61) 
4.  Replace the battery cover 
 

5.3. CLEANING 

To clean the instrument use a soft dry cloth. Never use a wet cloth, solvents or water, etc. 
The white plastic lens of the detector should be cleaned with a damp cloth when 
necessary. 
 

5.4.  END OF LIFE 

 

CAUTION: this symbol indicates that equipment and its accessories shall be 
subject to a separate collection and correct disposal. 

 

Summary of Contents for HT204

Page 1: ...Copyright HT ITALIA 2012 Release EN 1 01 09 02 2012 ENGLISH User s manual...

Page 2: ...5 R key 4 3 PREPARATION FOR USE 4 3 1 Initial 4 3 2 Power supply 4 3 3 Calibration 4 3 4 Storage 4 4 OPERATING INSTRUCTIONS 5 4 1 Measurement description 5 5 PREVENTIVE MAINTENANCE 5 5 1 General info...

Page 3: ...to the instruction manual An incorrect use may damage the luxmeter or its components 1 1 PRELIMINARY Before turning on the instrument make sure that the battery is correctly installed Replace the bat...

Page 4: ...um and minimum values Low battery indication 2 2 INSTRUMENT DESCRIPTION LEGEND 1 DATA HOLD active 2 MAX active 3 MIN active 4 Decimal point 5 Measured value 6 Measuring unit W m2 7 Measuring unit BTU...

Page 5: ...em Make sure that all standard accessories mentioned in paragraph 6 3 1 are included Should you have to return back the instrument for any reason please follow the instructions mentioned in paragraph...

Page 6: ...is is a precision instrument To guarantee its performances be sure to use it according to these instructions and keep it stored on suitable environmental conditions Do not expose it to high temperatur...

Page 7: ...tery 9V type 6LR61 Low battery indication is displayed when the battery is low Battery life About 100 hours carbon zinc Display Characteristics 3 1 2 digit LCD 2000 counts with OL indication Sample ra...

Page 8: ...ansit Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit auth...