HT Instruments QUICKLAN 6055 User Manual Download Page 5

 

 

QUICKLAN 6055

 

 

 

 

EN - 4

 

4. NOMENCLATURE 

4.1. INSTRUMENT 

DESCRIPTION 

 

 

 

CAPTION

1. RJ45 input terminal 
2. LCD display 
3. 

UTP

 key 

4. 

STP

 key 

5. 

GO

 key 

6. 

 key 

7. 

/  

key 

8. 

ON/OFF 

key 

9. Remote units #1 ~ #2 
 

Fig. 1: Instrument description 

 

4.2. DISPLAY 

DESCRIPTION 

 

 

CAPTION: 

1.  Type of selected cable 
2.  Low battery indication 
3.  Final test outcome 
4.  Running test indication 
5.  Fault test indication 
6.  Caution and remote unit 

number indications 

7.  Error numbers and input 

voltage indications 

8.  RJ45 cable couples and 

S shield  indications 

9.  Error type indications 
 

Fig. 2: Display description 

 

Summary of Contents for QUICKLAN 6055

Page 1: ...Copyright HT ITALIA 2016 Release EN 3 00 19 09 2017 ENGLISH User manual...

Page 2: ...and STP keys 5 4 3 3 GO key 5 4 3 4 and keys 5 4 3 5 Auto Power OFF feature 5 5 OPERATING INSTRUCTIONS 6 5 1 Cabling test verify 6 5 2 Cabling errors 7 5 3 Split pairs explanation note 9 6 MAINTENANCE...

Page 3: ...ticing applicable safety precautions must use this product Do not perform any measurement under conditions beyond the limits specified in this manual CAUTION Connect the tester only to inactive cables...

Page 4: ...o check it rapidly eventual damages may have occurred during transport Make sure that all standard accessories mentioned in 7 4 1 are included Should you have to return back the instrument for any rea...

Page 5: ...1 2 Fig 1 Instrument description 4 2 DISPLAY DESCRIPTION CAPTION 1 Type of selected cable 2 Low battery indication 3 Final test outcome 4 Running test indication 5 Fault test indication 6 Caution and...

Page 6: ...ch as FTP Foiled Twisted Pair cable STP Shielded Twisted Pair cable SSTP Shielded Shielded Twisted Pair cable and SFTP Shielded Foiled Twisted Pair cable CAUTION By default the selected cable is STP A...

Page 7: ...cable under test to the meter and to the remote unit by using if necessary through supplied patch cables see Fig 4 Fig 4 Instrument connection 4 Press GO key The message MEASURING is shown and the ins...

Page 8: ...s the presence of a voltage 0 2V on the RJ45 input it shows the message in the screen on the right and do not perform the test Eliminate the cause of the presence of voltage e g coupling due to the pr...

Page 9: ...een each other TRANSPOSED CROSSED PAIRS Two pairs are crossed MISWIRE Generic cabling error such as for example two conductors belonging to different pairs are exchanged SPLIT PAIRS The pin to pin cor...

Page 10: ...ge of two conductors belonging to different pairs The pin to pin correspondence seems intact but physically the conductors of two couples are split Such interaction hardly affects or even makes imposs...

Page 11: ...tery CAUTION Only skilled technicians can open the instrument and replace batteries Before removing batteries disconnect the test leads from any energized circuits to avoid electrical shocks 1 Switch...

Page 12: ...uto Power OFF after 4 minutes of idleness not disabled 7 3 ENVIRONMENT 7 3 1 Environmental conditions Working temperature 0 C 40 C 32 F 104 F Relative humidity 80 RH Storage temperature 0 C 40 C 32 F...

Page 13: ...not skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual may not be repr...

Reviews: