01/2014
Powerline HDS 230
13
HDS 230
Check
fi
rmness of all screw connections with
a torque wrench every 6 months and retighten
if necessary.
Employed screws:
Property class 8.8
Thread size
M 5
5,5
M 4
M 6
9,6
M 8
23
M 10
46
M 12
79
125
280
M 14
M 16
195
M 18
M 20
395
M 24
680
M 27
1000
M 30
1350
Tightening torque (Nm)
Property class
BY F. GROSS SCHRAUBEN GMBH & CO. (Screw and nut zinc coated:
μ
=0,125)
Property class
Property class
8,1
14
34
67
115
185
400
290
560
970
1450
1950
9,5
2,8
4,1
4,8
8.8
10.9
12.9
16
40
79
135
220
470
340
660
M 22
540
760
890
1150
1700
2300
Screw connections
Interval: 1000 working hours
Dispose of the machine in an environmentally sound way
at the end of its service life. Observe the current regula-
tions when doing this. As legislation is subject to ongoing
changes, we request that you contact your local authori-
ties at the appropriate time. As the manufacturer, HSM
would be glad to advise you on the disposal of your old
machine.
11 Disposal / Recycling