HSI PRX+12217 Series Installation And Owner'S Operation Manual Download Page 1

Specifications: 

Sensing Air Gap: 

0 to 3/16

 

Lateral Alignment: 

3/16

 

Max Current: 

0.5 A Resistive 

Max Voltage: 

60 VDC 

Min insulation Resistance: 

Input Voltage: 
Input Current: 

1000 MOhm 

7 to 25.2 VDC 
60mA, max 

Temperature Rating: 

-35 to +70 degrees C 

Wire Gauge 

22 AWG 

Suitable for outdoor use 

 

 

 

 

Wiring Diagram: 

Red 

Power 

Black 

Ground 

Blue 

Output 1 (Alarm) 

White 

Output 2 (Tamper)

 

     

 

        

 

 

State Diagram: 

State 

Orange 

Gray 

Brown 

Green 

Secure 

Open 

Closed 

Open 

Closed 

Insecure 

Closed 

Open 

Open 

Closed 

Tamper 

Open 

Closed 

Closed 

Open 

Alignment 

Closed

 

Open 

Closed 

Open 

 

Component View: 

 

Installation Plan: 

 

 

 

 

 

 

 

 

The sensor and tamper plate will be mounted to the door frame, close to 
the gap, without door interference. If the tamper plate is not installed, the 
sensor will only display a tamper state. For proper operation, the tamper 
plate must be mounted using the screws provided taking care to ensure 
that the magnet aligns with engraved target on the rear face of the 
sensor. The actuator will be mounted directly below the sensor. Be sure 
to aim the engraved targets at each other once fully installed. The sensor 
and actuator can be mounted on an inward or outward swinging door. 

For steel mounting surfaces, mount the sensor and actuator at the edge 
of the mounting surface or slightly overhanging the edge of the mounting 
surface.  This is particularly important when the air gap between the 
sensor and actuator is small.  False tamper indications may occur if this 
is not done. 

The operating gap must not be greater than 3/16”.  

Mounting Dimensions: 
 

 

 

Installation 

and 

Owner’s Manual 

PRX+12217 Series 

QA-721 REV A 

 

 

 

 

 