Specifications:
Sensing Air Gap:
0 to 3/16
”
Lateral Alignment:
3/16
”
Max Current:
0.5 A Resistive
Max Voltage:
60 VDC
Min insulation Resistance:
Input Voltage:
Input Current:
1000 MOhm
7 to 25.2 VDC
60mA, max
Temperature Rating:
-35 to +70 degrees C
Wire Gauge
22 AWG
Suitable for outdoor use
Wiring Diagram:
Red
Power
Black
Ground
Blue
Output 1 (Alarm)
White
Output 2 (Tamper)
State Diagram:
State
Orange
Gray
Brown
Green
Secure
Open
Closed
Open
Closed
Insecure
Closed
Open
Open
Closed
Tamper
Open
Closed
Closed
Open
Alignment
Closed
Open
Closed
Open
Component View:
Installation Plan:
The sensor and tamper plate will be mounted to the door frame, close to
the gap, without door interference. If the tamper plate is not installed, the
sensor will only display a tamper state. For proper operation, the tamper
plate must be mounted using the screws provided taking care to ensure
that the magnet aligns with engraved target on the rear face of the
sensor. The actuator will be mounted directly below the sensor. Be sure
to aim the engraved targets at each other once fully installed. The sensor
and actuator can be mounted on an inward or outward swinging door.
For steel mounting surfaces, mount the sensor and actuator at the edge
of the mounting surface or slightly overhanging the edge of the mounting
surface. This is particularly important when the air gap between the
sensor and actuator is small. False tamper indications may occur if this
is not done.
The operating gap must not be greater than 3/16”.
Mounting Dimensions:
Installation
and
Owner’s Manual
PRX+12217 Series
QA-721 REV A