background image

 

 

2.2 Rate of Change Icon 

The rate of change icon 

  detects rapid changes in temperature and humidity. If the 

arrow points upward, the temperature is increasing at a rate of +2°C per 30 minutes (or 
greater),  or  humidity  is  increasing  at  a  rate  of  +5%  per  30  minutes  (or  greater).  If  the 
arrow points downward, the temperature is decreasing at a rate of -2°C per 30 minutes 
(or less), or humidity is decreasing at a rate of -5% per 30 minutes (or less). 

3.  Indoor Thermo-Hygrometer Sensor Operation 

Note: 

The  indoor  sensor  has  three  buttons  for  easy  operation: 

MIN/MAX/-

  button, 

SET

 button, and

 CH/+

 button. 

3.1  Indoor Sensor Channel Setting 

Press and hold the 

CH/+

 button 3 seconds until the scroll icon

 shows. In scroll mode, 

press  the 

CH/+

  button  to  set  up  the  channel  number  1  through  8  channel.  Press  and 

hold the 

CH/+

 button 3 seconds to exit channel setting,  scroll icon disappears. 

 

Note: 

Set up the channel numbers

BEFORE

 inserting the receiver batteries, 

3.2  Min/Max Mode 

The  Min/Max  mode  displays  the  minimum  and  maximum  temperature  and  humidity 
(since reset of the unit) for the indoor sensor. 
 

1. 

Display  Maximum

.  Press  the 

MIN/MAX 

button  once  to  display  the  maximum. 

The 

MAX

 icon will be displayed. 

2. 

Clear Maximum.

 To reset the maximum values to the current values, 

press and 

hold

 the 

MIN/MAX

 button for 3 seconds. 

3. 

Display  Minimum

.  Press  the 

MIN/MAX 

button  again  to  display  the  minimum. 

The 

MIN

 icon will be displayed. 

4. 

Clear  Minimum.

 To reset  the minimum  values  to  the  current  values, 

press  and 

hold

 the 

MIN/MAX

 button for 3 seconds. 

To return to normal mode, press the 

MIN/MAX

 button again. 

 

3.3  Clearing Min/Max Daily 

The  minimum  and  maximum  can  be  set  to  clear  daily  (at  midnight)  or  manually.  Press 

and hold the 

SET

 button for 3 seconds to switch between 

and Clears Manually. 

 

When 

 is selected  min/max reading will be cleared every 

0:00

 from the time you 

clear it. 

3.4  Temperature Units of Measure 

The  default  temperature  units  of  measure  are  degrees  Celsius.  To  toggle  between 
degrees  Celsius  and  degrees  Fahrenheit,  press  and  hold  the 

MIN/MAX

  button  for  3 

seconds in normal mode. 
 
 

3.5  Backlight Operation

 

Summary of Contents for froggit FT-Comfort

Page 1: ...FT Comfort Manual FT Comfort Wireless Indoor 8 Channel Thermo Hygrometer ...

Page 2: ...ithium avoid rechargeable batteries in the back of the indoor sensor Figure 1 2 Insert two AAA batteries After inserting the batteries All of the LCD segments will light up for a few seconds to verify all segments are operating properly and then icon flashes once per 60 seconds thereafter Each time it flashes the sensor is transmitting data 3 Verify the correct channel number CH and temperature un...

Page 3: ... of Change indicator 7 Min Max Clears daily mode 8 Low power indicator 9 Humidity Calibrated Icon when the calibration is displayed 10 Humidity Comfort Colorful Icon 11 Relative Humidity 12 Channel 1 2 3 4 5 6 7 8 indictor 13 Min Max Record mode 2 Display Features 2 1 Comfort Colorful Icon The comfort icon is based on humidity ranges specified in Figure 3 RH 45 RH 45 65 RH 65 Dry Comfortable Wet F...

Page 4: ...ax Mode The Min Max mode displays the minimum and maximum temperature and humidity since reset of the unit for the indoor sensor 1 Display Maximum Press the MIN MAX button once to display the maximum The MAX icon will be displayed 2 Clear Maximum To reset the maximum values to the current values press and hold the MIN MAX button for 3 seconds 3 Display Minimum Press the MIN MAX button again to dis...

Page 5: ...d the SET and MIN MAX buttons at the same time for 3 seconds and the humidity value will begin flashing Press the CH button to increase the humidity and the MIN MAX button to decrease the humidity reading in 1 increments To rapidly increase or decrease the humidity reading press and hold the CH or MIN MAX button To return the humidity to the actual or uncalibrated measurement press the SET button ...

Page 6: ...atch the fluid thermometer 4 3 Sensor Operation Verification Verify the humidity match closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 10 the accuracy is 5 Allow about 30 minutes for both sensors to stabilize Verify the temperature match closely with the console and sensor array in the same location about 1 5m to 3m apart The sensors ...

Page 7: ...nication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communication 3 Line of Sight Rating This device is rated at 100 meter line of sight no interference barriers or walls but typically you will get 30 meter maximum under most real world installations which include passing through barr...

Page 8: ...ides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 0 to 60 C 1 C 0 1 C Indoor Humidity 10 to 99 5 only guaranteed between 20 to 90 1 5 3 Power Consumption Indoor sensor 2 x AAA 1 5V Alkaline or Lithium batteries not included Battery life Minimum 12 months for indoor thermometer hygrometer sensor Backlight often light may reduce the battery life...

Page 9: ...l acts as an RF shield or earth barrier down a hill Move the remote sensors around electrical noise generating devices such as computers TVs and other wireless transmitters if used indoor Move the remote sensor to a higher location Move the remote sensor to a closer location Temperature sensor reads too high in the day time Make sure the thermo hygrometer is mounted in a shaded area on the north f...

Page 10: ...his manual may contain errors and misprints However the information in this manual is regularly reviewed and corrections made in the next issue We accept no liability for technical errors or printing errors and their consequences All trademarks and copyrights are acknowledged www froggit de HS Group GmbH Co KG Escherstr 31 50733 Koeln Germany Telefon E Mail 0221 367 48 05 info hs group de Register...

Page 11: ...Escherstr 31 50733 D Cologne that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity for this product can be found at www froggit de or on request ...

Reviews: