Assembly Procedure
Document Ref:
AP3607157
Issue:
01
Issue Date:
19 December 2019
Page 6 of 21
Drawing:
Shown on Works Order
Description:
A2A SPACER AUSTRALIA
SI No: N/A, Issue 2, 26 Jun 2017
40
ASSY
Pack and label as per assembly drawing 3607216
Pack with a mask if needed. Refer to drawing for current packing and labelling details
50
ASSY
Force Gauge Test
Periodically the whole assembly should be checked for fit i.e. Mouthpiece Cap.
Push on a fully assembled Unit onto the Fixture. Bring the head down to just above the Unit and
clamp. Set the Head so that the probe comes down approximately 3mm from the Mouthpiece
edge.
Bring down the probe ensuring the setting is at zero and the Auto Peak is on.
Take a reading, this must be between 20-70Nm. Again reject any that fail to meet the spec.