background image

- 23 -

7.2 Ipv4

• Switch to the 

IPv4

 tab

•  Apply settings for the 

server IP address, port (lower) and subnet mask

 from the tool 

controller

• Adapt own 

IP address and port range

 to the TC

Summary of Contents for TC24IO

Page 1: ...CTIONS TC24IO Original operating instructions Release date March 2021 PC Software 2 0 4 0 and higher Firmware controller 0 0 2 4 and higher Firmare screwdriver 2 2 3 0 and higher Firmware rivet tool 2 7 7 0 and higher ...

Page 2: ...uarantee and liability 9 1 12 Copyright 10 2 Basic safety instructions 3 Overview 4 Commissioning 5 Notes 6 Setup TC24IO 6 1 Connecting to the HST Tool Manager 16 6 2 Network settings 17 6 2 1 Network settings for integration into an existing Wi Fi network 18 6 3 Process controls 19 6 4 Webinterface 21 7 Tool configuration 7 1 Wi Fi 22 7 2 Ipv4 23 7 3 Telegrams 24 8 Web interface 8 1 Tool status 2...

Page 3: ... 3 9 Technical data 10 EC declaration of conformity PAGE 29 PAGE 30 ...

Page 4: ... of at an environmentally compatible recycling facility Power devices do not go into the household trash Only for EU countries Directive 2012 19 EU Defective power devices must be collected separately and disposed of at an environ mentally compatible recycling facility ...

Page 5: ...ort and our technicians would be happy to assist you 1 1 Scope of delivery TC24IO incl antenna Cable for power supply Operating instructions 1 2 General information Read the device operating manual before initial operation Please pay particular attention to Chapter 2 General Safety Notes This manual should make it easier for the operator to get used to the device and of its intended application po...

Page 6: ...every operator If you have any further questions please feel free to contact us 1 3 Signs and symbols used The following signs and symbols will be used in this manual or on the product Symbol Explanation Read this operating manual do not dispose of with household waste EU conformity marking Registered trademark use only indoors Protection class II Intrinsically safe transformer Direct current Univ...

Page 7: ...es a potentially dangerous situation that can lead to serious injuries and or damage to the device NOTE Important and useful information on using this device 1 5 Technical terms and abbreviations used Abbreviation Meaning C Degrees Celsius temperature AC Alternate current DC Direct current Hz Hertz Frequency Li Ion Lithium ion battery technology mNN Meters above sea level height SN Serial number V...

Page 8: ...se HS Technik GmbH is not liable for any damage resulting from this 1 7 Improper use DANGER The use of this device for other purposes is not permitted Improper use or incorrect accessories can lead to dangers with unforeseeable consequences We accept no liability for damage and malfunctions resulting from non observance of these operating instructions and improper use 1 8 Duties of the operator Th...

Page 9: ...ability Guarantee and liability claims for personal injury and property damage are excluded if caused by one or more of the following improper use failure to observe these operating instructions improper installation commissioning operation and maintenance of the device Operating the device with defective safety devices or improperly installed or non func tioning safety and protective devices Fail...

Page 10: ...ormation which may not be fully or partially reproduced distributed or otherwise shared The copyright of these operating instructions is retained by HS Technik GmbH Manufacturer s address Im Martelacker 12 D 79588 Efringen Kirchen Telephone 49 0 7628 91 11 0 Fax 49 0 7628 91 11 90 E mail info hs technik com Internet www hs technik com ...

Page 11: ...and recognised technological safety guidelines However its use may jeopardise the health and life of the user or third parties or risk damage to other property WARNING The workplace must only be used in accordance with its intended use and in technically perfect condition NOTE Keep all safety information and instructions for the future NOTE Only have your device repaired by qualified professional ...

Page 12: ... 12 3 Overview IN OUT USB Input Output Supply ToolController Antenna 2 4GHz Status LEDs IN OUT Button Programming Reset ...

Page 13: ...ut 4 OV 24V Connection tool 11 12 Mini USB port 15 Status LED input 1 Status input 1 Release 16 Status LED input 2 Status input 2 17 Status LED output 1 OK indicator 18 Status LED output 2 NOK indicator 19 Status LED output 3 Error indicator 20 Status LED output 4 Connection tool indicator 22 Program button Programming restore tool settings Hold for 10 sec to restore factory default settings 24 Re...

Page 14: ...ngänge IN2 reserviert nicht belegt IN1 Freigabe Ausgänge OUT4 Verbindung Tool OUT3 Fehler OUT2 NIO OUT1 IO Output OUT4 connection tool OUT3 error OUT2 NOK OUT1 OK Input IN2 reserved not used IN1 release Input GND nominal voltage 24 V DC 1 Input Signal State Voltage range High 5 V Uhigh 24 V Undefined 0 8 V Uundef 5 V Low 0 V Ulow 0 8 V Output Signal State Voltage range High Uhigh 24 V Low Ulow OV ...

Page 15: ... tool is disconnected after connecting the connection status will not be updated Output OUT4 remains high The connection status is updated by the TC24IO when a telegram is sent again Error status OUT3 is set when telegrams to the tool are not answered with OK e g at the hardware initialization PowerRiv Here the TC24IO Enable telegram is answered with HW ...

Page 16: ... 6 Setup TC24IO 6 1 Connecting to the HST Tool Manager Connect mini USB to Laptop PC Start HST Tool Manager To start the readout press the Read button Open the settings menu by pressing the Settings button ...

Page 17: ...ork settings Define SSID and network key Set IP address of the TCs with port number Set up subnet mask A standard gateway is not required everything is 0 Save changes in the TC by pressing the Apply changes button ...

Page 18: ... be used Enter the network key of the Wi Fi network to be used Select the appropriate channel Specify the IP address of the TC with the port number The IP range used by the TC24IO and the tool can also be different from the IP range of the Wi Fi network it must then be ensured that a correct subnet mask is entered Set the standard gateway IP address of the access point Save changes in TC with the ...

Page 19: ...3 is to be released 1003 must be entered Count Number of screw connection rivets per release ID Entry mandatory e g 1 entry as customized text max 64 characters no special characters like semicolon or space TorqBee release mode 0 never 1 only after NOK 2 after OK NOK 4 released up to 1st OK NutBee release mode 0 never Failed attempts max customized entry of the max permitted repeat attempts NOK be...

Page 20: ...ible 3 Off program Settings correspond to the program of the tool selection only possible via web interface 4 1 OK Release until 1 OK possible NOK behaviour Value Designation Description 0 1 x NOK Cancel Cancel as soon as NOK 1 1 x NOK NIO Once NOK leads to total NOK 2 1 x SC NOK NIO A screw NOK leads total NOK 3 Never NOK NOK NEVER leads to NOK always OK ...

Page 21: ... 21 6 4 Webinterface Set login name and password By default the login name and password are always set to admin Set desired auto logout time ...

Page 22: ...ation tab after pressing the Settings button Modify the following settings on the Wi Fi tab Type of authentication WPA WPA2 SSID Apply settings from the TC24IO Network key Apply settings from the TC24IO Region automatic Band Select 2 4 GHz Transmission power select according to the desired range Channel Apply settings from the TC24IO 7 Tool configuration ...

Page 23: ... 23 7 2 Ipv4 Switch to the IPv4 tab Apply settings for the server IP address port lower and subnet mask from the tool controller Adapt own IP address and port range to the TC ...

Page 24: ... 24 7 3 Telegrams Switch to tab telegrams Next to send telegram select TG1 TG Block PR must be activated Send ALL OK NOK must be activated 8 Configuration telegrams ...

Page 25: ... coded indicators under Tool status show the TC s server status and the connection to the tool Red Inactive not connected Green active connected Program displays the program set for the tool Quantity displays the frequency of the program repetitions per release The tool can be released blocked using the Enable and Disable buttons 8 Web interface ...

Page 26: ... 26 8 2 Login On the login tab users can log in to the web interface via the defined user settings Default settings User admin Password admin ...

Page 27: ... 27 8 3 Net setup Several TC settings can be viewed modified here ...

Page 28: ... ToolStatus tab Connect PC mobile device to TC24IO via Wi Fi Call up the webinterface tab Net Setup and change to tab Test EA Activate test mode via boxes and switch outputs Check the status LEDs on the TC24IO and TM Call Alternative Rider Test EAs in TM and with Web Interface Web interface Tool Status Test EAs Tool Status Web interface Test EA ...

Page 29: ...ategory IP20 Protection class 3 Protective low voltage Operating temperature 0 C T 55 C Relative humidity 20 φ 60 Transport and storage 20 C T 60 C 0 φ 75 Electrical properties Property Description Function comment Power supply 24 V DC 1 Power supply Service max 24 W Voltage inputs 0 24V see chapter 4 Voltage outputs 0 24V see chapter 4 Current outputs max 100 mA Per output ...

Page 30: ...ion this declaration will be null and void Description of the device Controller Type description TC24IO Manufacturer HS Technik GmbH Im Martelacker 12 D 79588 Efringen Kirchen Directives 2014 30 EU 2014 35 EU 2011 65 EG 2001 95 EG Angewandte Normen EN 55032 2015 EN 61000 4 2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2012 EN 61000 4 6 2014 EN 61000 4 8 2010 EN 61000 6 2 2005 AC 2005 09 EN...

Page 31: ... 31 Notes ...

Page 32: ...0 7628 91 11 0 Telefax 49 0 7628 91 11 90 E Mail info hs technik com Internet www hs technik com The technical data in these printed material provide support but are not guaranteed Constructional changes reserved Our construction recommendations are non binding 23032021 ...