HRT VS4-YC User Manual Download Page 4

 

 

VS4-YC User’s Manual

 

2. Installation 

1.

 

Plug in the desired number of S-Video sources to the S-Video inputs on the 
back of the VS4-YC. 

2.

 

Connect an output device to the S-Video output on the back of the VS4-
YC.  

3.

 

Connect the included RS-232 cable to a PC or other Serial control device if 
so desired. 

4.

 

Connect the included power supply to the jack on the rear of the unit.  

5.

 

Apply AC to the power supply 

6.    Turn on your output video display and all video sources 

 

3. Operation 

3.1 Modes of Operation 

Scan Mode -

 Will cycle through and select each S-Video signal for a 

programmed number of seconds (1 to 60), and then switch to the next S-Video 
input.  

Normal Mode -

 S-VIDEO inputs are selected based on user input (default). 

The VS4-YC can only be in one of these modes at a time. 

3.2 Front-Panel Switches 

The first function of the front panel buttons is to switch from one S-Video signal 
to another. Just press the button and the S-Video signal you selected will be 
routed to the output. If there is no S-Video signal to be displayed then you will 
see a black screen. The VS4-YC will enter Normal Mode any time a single front 
panel button is pressed. 

The second use of the front panel buttons is to put the VS4-YC into Scan Mode. 
Press buttons 3 and 4 simultaneously and the VS4-YC will enter Scan Mode. 
The time interval between switching will be the time interval last specified via 
Hyper Terminal. If no interval has been specified then the default is 5 seconds.  

The third use of the front panel buttons is to reset the VS4-YC to the factory 
default settings. Press button 1 and 4 simultaneously for 3 seconds. This will 
turn off scan mode and set the scanning interval to the default time of 5 seconds. 
This will also un-blank the outputs. 

Summary of Contents for VS4-YC

Page 1: ... or fax 714 641 6698 Mail order Hall Research Technologies 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail info hallresearch com 4 x 1 S Video Switch with Serial Control VS4 YC User s Manual H Ha al ll l R Re es se ea ar rc ch h T Te ec ch hn no ol lo og gi ie es s I In nc c UMA1009 Rev B ...

Page 2: ... FCC rules Harmful interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures are necessary to correct the interference European Union Declaration of Conformity This product has been tested and shown to comply with the requirements of the Europea...

Page 3: ... The unit features 250 MHz amplifiers for a clear and crisp image The output can be placed in scan mode either from the front panel by pressing two buttons simultaneously or via a serial command In this mode the output displays each input channel for a few seconds and cycles through all inputs The output can also be blanked via a serial command 1 2 Features Serial Port for Control via external dev...

Page 4: ... time 3 2 Front Panel Switches The first function of the front panel buttons is to switch from one S Video signal to another Just press the button and the S Video signal you selected will be routed to the output If there is no S Video signal to be displayed then you will see a black screen The VS4 YC will enter Normal Mode any time a single front panel button is pressed The second use of the front...

Page 5: ...ing Seconds between switching 1 60 To this question you must input a number between 1 and 60 then press enter Any other input will cause this question to be repeated Pressing b will blank the S Video output and mute the line level Stereo output from the VS4 YC until the un blank command is received Pressing u will un blank the S Video output and un mute the line level Stereo output from the VS4 YC...

Page 6: ...A number first 5 Specifications Video Gain Level Unity Gain 1V p p for Y 0 3 V p p for C Video Bandwidth 250 MHz 3 dB Input Impedance Video 75 Ω on Y and C Serial Control 4800 Baud 8 bit 1 stop bit no parity Temperature Operating 32 to 122 F 0 to 50 C Storage 40 to 158 F 40 to 70 C Enclosure Steel MTBF 85 000 hours calculated estimate Power From utility power mains outlet through included external...

Page 7: ......

Page 8: ...chnical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research Technologies 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail info hallresearch com CUSTOMER SUPPORT INFORMATION Products Designed and Made in the USA ...

Reviews: