2.2 INPUT PANEL AND INSTRUCTION 

 

2.2.1 FAN 

For cooling the inverter during operation 
 

2.2.2 TERMINAL CONNECTOR 

Use red battery cable to connect (+) of the battery to the (+) terminal of the inverter. Then use 
the black battery cable to connect the (-) of the battery to the (-) terminal of the inverter. 
Tighten the screws of the DC input cables regularly. 
 
When connected to a battery, please make sure to turn on inverter first, before turning on the 
connected appliance(s). When using the inverter with several appliances at the same time, 
turn the appliances on separately after the inverter is already turned on. This will ensure that 
the inverter doesn’t have to deliver all start up currents for all the loads at once . 

 

CAUTION! 

Please attend to 220V AC power is potentially lethal, don’t work on AC wiring while the 
wiring is connected to the inverter (even if it is switched off) unless the DC power 
source is physically disconnected from the inverter . Also don’t work on AC wiring if it 
is connected to another AC power source such as a generator or the utility line . 

 
CAUTION!  
Do not reverse input!  Don’t use “alligator-clips” and always ensure the ON/OFF switch 
on the output panel of the inverter is switched to the OFF position before connected 
the battery or other DC power source! 

 

 

Summary of Contents for HQ-INV2500/12

Page 1: ...Q INV2500 12 HQ INV2500 12F HQ INV2500 24 HQ INV2500 24F 12V DC to 230V AC Soft Start Power Inverter 24V DC to 230V AC Soft Start Power Inverter 2500 WATT CONTINUOUS OUTPUT POWER MANUAL 021895 ENGLISH...

Page 2: ...00W surge output 2500W continue 5000W surge output Input voltage DC10 16V DC20 30V Output voltage AC 230V AC 230V Output waveform Modified sine wave Modified sine wave Output frequency 50 or 60HZ 50 o...

Page 3: ...perature between 0 25 C 3 To avoid fire hazard and overheating do not cover or obstruct the ventilation openings of the inverter Regularly check the ventilation openings because these especially colle...

Page 4: ...ry and switched on the power indicator illuminates green color ready for use 2 1 6 OVER TEMPERATURE indicator The over temperature indicator illuminates in yellow when the inverter is overheated Also...

Page 5: ...ppliances on separately after the inverter is already turned on This will ensure that the inverter doesn t have to deliver all start up currents for all the loads at once CAUTION Please attend to 220V...

Page 6: ...arately derived AC sources such as inverters and generators have their neutral conductors tied to ground in the same way that the neutral conductor from the utility line is tied to ground at the AC br...

Page 7: ...the case or cut out the cord 7 CAUTION Do not use the inverter with the following rechargeable appliances Two particular types of chargers for small nickel cadmium batteries can be damaged if connect...

Page 8: ...2 245 EEC 95 54 EC e13 72 245 95 94 1895 00 EMC 98 336 EEC EN 61000 6 3 2001 EN 55014 1 EN 61000 3 2 3 EN 61000 6 1 2001 EN 55014 2 EN 61000 4 2 4 5 6 11 LVD 73 23 EEC EN 60950 1 2001 EN 61558 1 1997...

Page 9: ...8 www hqproducts info...