VDPLWB
V. 01 – 09/02/2015
9
©Velleman nv
Use a DMX signal amplifier when the signal cable distance exceeds
60 meters (200 ft). Maximum recommended number of devices on a
serial data link is 32 devices.
A DMX terminator is recommended for installations where the DMX
cable has to run a long distance or is in an electrically noisy
environment (e.g. discos). The terminator prevents corruption of the
digital control signal by electrical noise. The DMX terminator is simply
an XLR plug with a 120 Ω resistor between pins 2 and 3, which is then
plugged into the XLR output socket of the last device in the chain.
8.
Cleaning and Maintenance
The VDPLWB does not need any particular maintenance. However, it is
advisable to clean it occasionally to keep it looking like new.
9.
Troubleshooting
problem
possible solution
power/DMX LED does not
blink on the transmitter
check the connection to the
DMX controller and the fixture
LED does not blink on the
receiver
make sure it is set up
correctly
switch off and switch on the
receiver
no LEDs blinking
make sure the power cord is
plugged in correctly
10.
Technical Specifications
power supply
9 VDC (adapter incl.)
operation frequency
2.4 GHz
DMX channels
512
antenna connection
RP-SMA