![HQ Power VDPLOF1203 User Manual Download Page 4](http://html1.mh-extra.com/html/hq-power/vdplof1203/vdplof1203_user-manual_2176791004.webp)
VDPLOW2403_v2
HQPOWER™
4
Address Setting: 002
1.
Press the S button; the red LEDs are on: you can start to set the address.
2.
Press numeric button #0; the green LEDs are on: 0 (hundreds) setting successful.
3.
Press numeric button #0; the blue LEDs are on: 0 (tens) setting successful.
4.
Press numeric button #2; all the LEDs are on: complete setting successful.
Detailed DMX Values per Channel
Channel Function From
To
Description
1
Red
0
255
From 0 – 100 %
2
Green
0
255
From 0 – 100 %
3
Blue
0
255
From 0 – 100 %
4
Dimmer
0
255
From 0 – 100 %
5 Shutter
0 10
Closed
11 255
S>F
strobe
DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side
to the male 3-pin XLR input of the
VDPLOW2403
. Multiple
VDPLOW2403
s can be linked through
serial linking. The linking cable should be a two-core screened cable with XLR input and output
connectors.
DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has
to run a long distance or is in an electrically noisy environment (e.g. discos).
The terminator prevents corruption of the digital control signal by electrical
noise. The DMX terminator is simply an XLR plug with a 120
Ω
resistor
between pins 2 and 3, which is then plugged into the XLR output socket of
the last device in the chain.
Please see illustrations.
DMX Start Address Setting
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This start address is the channel number from which the device starts to “listen” to the DMX
controller. Enter the correct number and read it from the display located on the base of the
VDPLOW2403
.
You can use the same starting address for a whole group of devices or enter an individual one for
every device.
When all devices have the same address, all the
VDPLOW2403
s will “listen” to the control signal on
one particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set different addresses, each device will “listen” to a separate channel
number. Changing the settings of one channel will only affect the device in question.
In the case of the 5-channel
VDPLOW2403
, you will have to set the start address of the first
VDPLOF1203
to 1, the second
VDPLOW2403
to 6 (1 + 5), the third to 13 (6 + 5) and so on.
7. Cleaning
and
Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling,
suspension, trussing) should not be deformed, modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician
maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.