VDL250MG
Rev.
01
09.11.2010
©Velleman nv
5
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting
supports, do not change the location of the connections, …
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician service the
device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts apart from the lamp and the fuse (see “
Installation
”).
8. Contact your dealer for spare parts if necessary.
7. Technical Specifications
power supply
230VAC ~ 50Hz
power consumption
max. 270W
fuse
2.5A, 250Vac (5 x 20mm) (order code
FF2.5N
)
dimensions
320 x 220 x 130mm
weight 6kg
lamp
1 x 24V / 250W ELC G6.35 (order code LAMP250/24ELCE (incl.) or
LAMP250/24ELC (Philips)(not incl.) or LAMP250/24ELC5H (Philips
– long life)(not incl.))
max. ambient temperature
45°C
max. housing temperature
130°C
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulted from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.hqpower.eu. The information in this manual is subject to change without prior notice.
©
COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.