HN-3208SR-000R User Manual
36
Setting whether to check and transmit check-bit
Code 39 barcode data can contain no check-bit; if there is a check that is the last 1 character of
the data. The check-bit is a value calculated from all the data to verify that the data is correct.
Setting whether to check
No Check (Default) Check
Setting whether to transmit check-bit
Transmit No Transmit (Default)
ASCII barcode recognizing range setting
Code 39 barcode data can include all ASCII characters, but the scanner only recognizes some
ASCII characters by default. You can turn on the ability to read full ASCII characters by setting.
Turn off Full ASCII Recognizing (Default) Turn on Full ASCII Recognizing
Code 39 converse Code32 setting