  Installation

  Cleaning

  Optional Accessories

  Disclaimers

Remove all packaging from the product before commencing installation. Ensure the circuit has been isolated from the 240V mains before 

commencing work. 

1.   Choose a suitable mounting location. There must be adequate clearances in the wall/ceiling to accommodate the Draft-stopper and/or 

ducting. Refer to section 2 for further information.

2.  If ducting through the wall to the outside, refer to instructions in the wall duct kit. Note: the wall kit is available separately, please refer  

to Optional Accessories section.

3. The time delay module that is included in EFT150SQSWE is available separately (EF100/150TD), adjustable from 1-to-29 minutes.
4.  Make a circular 160mm hole in the wall/ceiling.
5.  Remove front cover / fascia by removing fixing screw and cap on the underside of the cover.
6.  Remove draft-stopper if not required. Note that the draft-stopper (when fitted) has an effect on the airflow.
7. Make the electrical connections (as per Figures below). 

8. Ensure orientation of fan is with arrow pointing

up.

9. Fix fan firmly to the wall with the 4 screws provided. 
10. Replace front cover/fascia and tighten fixing screw. Replace cap.
11.  Switch on and test function. Use a paper tissue held against fan 

inlet to verify suction.

This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used. Ensure the fan is switched off from 

the mains power supply before removing the grille / fascia.

Timer Adjustment
The default setting 

is to 1min (approx). 

Adjust to dedsired 

time delay

R621/6D – 150mm wall duct kit 

EF100/150TD – Time delay module allows the fan to run for a set period, adjustable between 1 - 29 mins, after the switch has been turned off.

1. This product must be installed and used as per these instructions. 2. This product is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the appliance. 3. This product is intended for household use and similar purposes. It is not suitable for use in 

an environment heavily laden with dust. Under these conditions the life of the fan motor can be significantly reduced. 4. This product should not be enclosed in thermal insulation 

as it may cause the unit to overheat. 5. This product has been designed to operate in ambient temperatures -10°C to 40°C. 6. This product contains no serviceable parts and no 

attempt should be made to repair it. If the product is faulty it should be discarded. 7. Airflows listed in this product indicate the product performance. Refer to the BCA (Building 

Code of Australia), or similar, for the appropriate airflow required for a particular installation. 8. Ventilation products must have an adequate source of external air to ensure correct 

performance. 9. Consideration must be taken in the installation of ducts to ensure that condensation that will form in the duct will not run back into the fan housing. 10. Precautions 

must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances. 11. This product has been designed for domestic or similar 

uses and is not suitable for a commercial installation. 12. This product is not suitable for installation in hazardous and/or corrosive areas. 13. Extended exposure to UV rays (such 

as exposure to direct sunlight) may cause discolouration of this product. 14. The material in this product may vary in colour from batch to batch. Colour matching from one batch to 

another cannot be guaranteed. 15. This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property remains the 

property of Legrand in all cases. 16. Legrand reserves the right to modify the specification of this product at any time.

  Figure 2. Fan with timer module and light fitting

Active

L

N

LS

Neutral

Connection from rear – bring mains wiring through  

cable entry hole.

Connection from side (Fan only) – use twin flat core 

(H03VV-H2) or circular core (H05VV-F) 2 x 0.75mm

2  

and place under cable clamp provided.

Timer

LE06397A

TB

 

LEG0703_B

LE06397A

TB

MINIMUM

(1 minute)

MAXIMUM

(29 minute)

LS

N

L

3

2

1

Fan 

mounting 

orientation

Cable entry  

from rear

Cord entry from 

side for plug and 

lead (knock-out 

provided)

LS   Switched Active 

from wall switch

N  Neutral
L    Unswitched Active 

(only used when 

timer module  

is fitted)

Fixing screw 

position of fascia

  Figure 1.

LS

N

L

3

2

1