QuickSpecs
HPE ProLiant MicroServer Generation 8 (Gen8)
Technical Specifications
Page 26
change is 10°C/hr (18°F/hr). The upper limit
may be limited by the type and number of
options installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate
of change is 20°C/r (36°F/hr)
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be
limited by the type and number of options
installed. Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
(Fully Loaded)
Idle
150W PSU
LWAd
3.9 BELS
LpAm
21.0 dBA
200W PSU
LWAd
3.4 BELS
LpAm
18.0 dBA
Operating
150W PSU
LWAd
3.9 BELS
LpAm
21.0 dBA
200W PSU
LWAd
3.5 BELS
LpAm
18.0 dBA
Acoustic Noise
(Lightly Loaded)
Idle
150W PSU
LWAd
3.4 BELS
LpAm
18.0 dBA
200W PSU
LWAd
3.3 BELS
LpAm
18.0 dBA
Operating
150W PSU
LWAd
3.5 BELS
LpAm
18.0 dBA
200W PSU
LWAd
3.4 BELS
LpAm
18.0 dBA
Emissions Classification
(EMC)
FCC Rating
Class B
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN