HPE Smart Storage Battery configuration error
Symptom
Any HPE server configured with an HPE Smart Storage Battery that receives a POST error message or
an IML message.
Cause
The number of battery-backed devices exceeds the installed HPE Smart Storage Battery capacity.
Action
1.
Do one of the following:
• Ensure that the HPE Smart Storage Battery is fully charged. It may take up to 120 minutes in a
powered server or chassis for the HPE Smart Storage Battery to charge to support the number of
battery-backed devices in the server or chassis.
• If the charge level is insufficient to support the battery-backed devices installed in the server or
chassis, the HPE Smart Storage Battery output might not be enabled while the battery is charging.
It might take up to 120 minutes in a powered server or chassis for the battery to charge fully.
• Verify the HPE Smart Storage battery status in iLO.
• Remove some of the battery-backed devices using the HPE Smart Storage Battery. HPE Smart
Array Controllers and NVDIMMs use the HPE Smart Storage Battery.
For more information, see the server maintenance and service guide for your product on the
Hewlett Packard Enterprise website:
◦ HPE ProLiant Gen 10 (
http://www.hpe.com/info/proliantgen10-docs
)
◦ HPE Synergy (
http://www.hpe.com/info/synergy-docs
)
More information
Server user guide on page 167
HPE Smart Storage Battery failure
Symptom
Any HPE ProLiant server configured with an HPE Smart Storage Battery for HPE Smart Array Controllers
receives a POST error message or an IML message indicating a cache module failure or an HPE Smart
Storage Battery failure.
Cause
• Communication with the HPE Smart Storage Battery failed.
• The HPE Smart Storage Battery output is not enabled.
126
HPE Smart Storage Battery configuration error