Description
Chassis
Fan configuration Number of drives
supported by the
server
Maximum inlet
ambient
temperature
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
Optical cable: 25°C
(77°F)
Copper cable: 35°C
(95°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Optical cable: 28°C
(82.4°F)
Copper cable: 35°C
(95°F)
Ethernet adapters
with QSFP28
transceiver/
InfiniBand adapters
with EDR speed
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
Optical cable: Not
supported
Copper cable: 28°C
(82.4°F)
Optical cable: Not
supported
Copper cable: 25°C
(77°F)
Optical cable: 25°C
(77°F)
Copper cable: 35°C
(95°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Optical cable: 22°C
(71.6°F)
Copper cable: 35°C
(95°F)
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
Optical cable: 22°C
(71.6°F)
Copper cable: 35°C
(95°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Optical cable: 22°C
(71.6°F)
Copper cable: 35°C
(95°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.