Media Module adapters
Description
Chassis
Fan configuration Number of drives
supported by the
server
Maximum inlet
ambient
temperature
Media Module
10Gb 2P
568FLR-MMSFP
+
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
30°C (86°F)
5 to 6 drives
Not supported
0 to 4 drives
35°C (95°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
35°C (95°F)
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
35°C (95°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
35°C (95°F)
Media Module
10Gb 2P
568FLR-MMT
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
30°C (86°F)
5 to 6 drives
Not supported
0 to 4 drives
35°C (95°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
30°C (86°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
Specifications