If the component is installed in server 1, and the server is installed in the Apollo DX2200 Gen10 Chassis, drive blanks
must be installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3, and the server is
installed in the Apollo DX2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 4-2. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 35.
FlexibleLOM adapters with SFP+, SFP28 or QSFP transceivers
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
Apollo DX2200
Gen10 Chassis
(12 LFF backplane)
Redundant and
nonredundant
Optical cable: Not
supported
Copper cable: 30°C
(86°F)
Not supported
Optical cable: 25°C
(77°F)
Copper cable: 30°C
(86°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Optical cable: 25°C
(77°F)
Copper cable: 30°C
(86°F)
Apollo DX2800
Gen10 Chassis
(24 SFF backplane
with SAS expander)
Redundant and
nonredundant
0 to 24 drives
Optical cable: 22°C
(71.6°F)
Copper cable: 30°C
(86°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Optical cable: 25°C
(77°F)
Copper cable: 30°C
(86°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1, and the server is installed in the Apollo DX2200 Gen10 Chassis, drive blanks
must be installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3, and the server is
installed in the Apollo DX2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 4-2. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 35.