Systems Insight Display
LED and color
Health
LED
System
power LED
Status
Power supply (amber)
Amber
Green
One or more of the following
conditions may exist:
• Redundant power supply is
installed and only one power
supply is functional.
• AC power cord is not plugged into
redundant power supply.
• Redundant power supply fault
• Power supply mismatch at POST
or power supply mismatch through
hot-plug addition
Power cap (off)
—
Amber
Standby
Power cap (green)
—
Flashing
green
Waiting for power
Power cap (green)
—
Green
Power is available.
Power cap (flashing amber)
—
Amber
Power is not available.
IMPORTANT:
If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test
each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a
bank with a known working DIMM.
Rear panel components
Item
Description
1
Primary riser slots 1-3 (Optional drive cage)
2
Optional riser slots 4-6 (Optional drive cage)
3
Optional riser slots 7-8 (Optional drive cage)
4
Power supply 1
5
Power supply 2
6
Video port
Table Continued
116
Component identification
Summary of Contents for ProLiant DL388 Gen10
Page 37: ...Customer self repair 37...
Page 38: ...38 Customer self repair...
Page 39: ...Customer self repair 39...
Page 147: ...Option 1 System board Option 2 Controller Option 3 not shown SAS Expander Cabling 147...
Page 149: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 149...
Page 151: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 151...
Page 152: ...Box 3 Cable routing Front 2SFF NVMe drive option for SFF 152 Cabling...