13. Install the fan cage.
16. Slide the server into the rack.
17. Connect each power cord to the server.
18. Connect each power cord to the power source.
The installation is complete.
Drive cage options
Installing a front 8NVMe SSD Express Bay drive cage
Observe the following:
• The drive cage can be installed in any box. This procedure covers installing the drive cage in box 1.
• When installing in box 1, the NVMe riser must be installed in the tertiary PCIe slot.
• When installing in box 2, the NVMe riser must be installed in the secondary PCIe slot.
• When installing in box 3, the NVMe riser must be installed in the primary PCIe slot.
Prerequisites
An associated NVMe riser and high-performance fans are required when installing this option.
Procedure
1.
Observe the following alerts.
Hardware options installation
98