HPE JH182A User Manual Download Page 7

Figure 3 Installing the LSWM124XGT2Q interface module 

 

 

Removing the interface module 

 

CAUTION: 

 

Before you remove the interface module, remove the cable 
from it to avoid cable damage. 

 

If you are not to install a new interface module,, install a filler 
panel in the slot to prevent dust and ensure good ventilation in
the device. 

 
To remove the interface module: 

1. 

Prepare an anti-static bag. 

2. 

Press the latch to release the ejector lever 

3. 

Rotate outward the ejector lever, as shown by callout 1 in 

Figure 

4

.  

4. 

Pull the interface module slowly out of the interface module slot, 
as shown by callout 2 in 

Figure 4

5. 

Place the removed interface module in the anti-static bag. 

Figure 4 Removing the LSWM124XGT2Q interface module 

 

 

Summary of Contents for JH182A

Page 1: ...escription Alias JH182A HPE 5930 24 port 10GBASE T and 2 port QSFP with MACsec Module LSWM124X GT2Q Overview Each LSWM124XGT2Q interface module provides 24 10GBASE T ports and two QSFP ports Figure 1...

Page 2: ...0 m 328 08 ft over category 6A or above twisted pair cable Compliance standards IEEE 802 3an IEEE 802 3ab QSFP ports The QSFP ports on the LSWM124XGT2Q interface module support the following transceiv...

Page 3: ...Hz km Max transmission distance JG325B Multi mode 50 125 2000 100 m 328 08 ft 4700 150 m 492 13 ft JG709A Multi mode 50 125 2000 300 m 984 25 ft 4700 400 m 1312 34 ft JG661A Single mode 9 125 N A 10 k...

Page 4: ...5 m 16 40 ft 40 Gbps NOTE When you install the interface module on the HPE FlexFabric 5930 4 Slot Switch JH179A HPE FlexFabric 5930 4 Slot TAA Switch JH188A and HPE FlexFabric 5940 4 Slot Switch JH398...

Page 5: ...ption LED status Description Steady green A transceiver module or cable has been correctly installed The port has a link and is operating at 40 Gbps Flashing green The port is sending or receiving dat...

Page 6: ...nstall the interface module remove the filler panel if any from the target slot Keep the removed filler panel for future use To install the interface module 1 Unpack the interface module Figure 2 LSWM...

Page 7: ...he slot to prevent dust and ensure good ventilation in the device To remove the interface module 1 Prepare an anti static bag 2 Press the latch to release the ejector lever 3 Rotate outward the ejecto...

Page 8: ...the interface module fails to operate correctly perform the following steps 1 Reinstall it following the installation procedures described in this document 2 If the problem persists contact Hewlett P...

Reviews: