background image

Fan trays overview 

LSWM1FANSC fan tray 

Overview 

The LSWM1FANSC (JC682A) fan tray blows cool air from the back (power side) to the front (port 
side). It comprises two separate fans. The LSWM1FANSC features small size, fast heat dissipation, 
and hot swapping. It can automatically adjust the fan speed, providing powerful heat dissipation for 
the device. 

Figure 1 LSWM1FANSC fan tray 

 

(1) Captive screw

 

(2) Airflow direction label

 

(3) Fan tray handle

 

 

 

Specifications 

Table 1 LSWM1FANSC specifications 

Item Specifications 

Fans 

Two 40 × 40 × 28 mm (1.57 × 1.57 × 1.10 in) fans 

Airflow direction 

Fans blow air from the power module side to the 
network port side 

Max fan speed 

18500 R.P.M 

Max airflow 

45 CFM 

Max power consumption 

19.5 W 

Voltage 12 

V

 

3

2

1

Summary of Contents for JC682A

Page 1: ...HPE LSWM1FANSC LSWM1FANSCB Fan Assemblies Installation Part number 5998 1615R Document version 6W101 20160115 ...

Page 2: ... and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterpris...

Page 3: ...moving a fan tray 4 Safety guidelines 4 Tools required 4 Installing a fan tray 4 Removing a fan tray 5 Document conventions and icons 7 Conventions 7 Network topology icons 8 Support and other resources 9 Accessing Hewlett Packard Enterprise Support 9 Accessing updates 9 Websites 10 Customer self repair 10 Remote support 10 Documentation feedback 10 ...

Page 4: ...omatically adjust the fan speed providing powerful heat dissipation for the device Figure 1 LSWM1FANSC fan tray 1 Captive screw 2 Airflow direction label 3 Fan tray handle Specifications Table 1 LSWM1FANSC specifications Item Specifications Fans Two 40 40 28 mm 1 57 1 57 1 10 in fans Airflow direction Fans blow air from the power module side to the network port side Max fan speed 18500 R P M Max a...

Page 5: ...r side It comprises two separate fans The LSWM1FANSCB features small size fast heat dissipation and hot swapping It can automatically adjust the fan speed providing powerful heat dissipation for the device Figure 2 LSWM1FANSCB fan tray 1 Captive screw 2 Airflow direction label 3 Fan tray handle Specifications Table 2 LSWM1FANSCB specifications Item Specifications Fans Two 40 40 28 mm 1 57 1 57 1 1...

Page 6: ...flow 45 CFM Max power consumption 19 5 W Voltage 12 V Operating temperature 10 C to 70 C 14 F to 158 F Relative humidity 5 to 95 non condensing Storage temperature 40 C to 75 C 40 F to 167 F Relative humidity 5 to 95 non condensing ...

Page 7: ...Tools required Prepare the following tools when installing and removing a fan tray Phillips screwdriver ESD preventive wrist strap Installing a fan tray TIP Before installing a fan tray make sure the air flow of the fan tray is as required 1 Wear an ESD preventive wrist strap and make sure it makes good skin contact and is well grounded 2 Take the fan tray from the package and check that the fan t...

Page 8: ...ity Do not touch rotating fans when replacing a fan tray with the device running 1 Wear an ESD preventive wrist strap and make sure it makes good skin contact and is well grounded 2 Face the fan tray to be removed from the device Loosen the captive screws on the fan tray with a Philips screwdriver until the captive screws fall off the device as shown in callout 1 in Figure 4 3 Grasping the handle ...

Page 9: ...e out the fan tray after the fans stop rotating Do not touch the fans even if the fans stop rotating to avoid affecting the fan balance which can cause greater fan operation noise To ensure normal operation of the device install a new fan tray within two minutes after the fan tray is removed if you replace a fan tray with the device running 1 2 ...

Page 10: ...st one x y Asterisk marked square brackets enclose optional syntax choices separated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names button names field name...

Page 11: ...Represents an access controller a unified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Represents a wireless terminator unit Represents a wireless terminator Represents a mesh access point Represents omnidirectional signals Represents directional signals Represents a security product such as a firewall UTM multiservice security gateway...

Page 12: ... provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update method To download product updates go to either of the following Hewlett Packard Enterprise Support Center Get connected with updates page www hpe com support e updates Software Depot website www hpe com support softwaredepot To view and up...

Page 13: ...lf repair Hewlett Packard Enterprise customer self repair CSR programs allow you to repair your product If a CSR part needs to be replaced it will be shipped directly to you so that you can install it at your convenience Some parts do not qualify for CSR Your Hewlett Packard Enterprise authorized service provider will determine whether a repair can be accomplished by CSR For more information about...

Page 14: ...r feedback include the document title part number edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices page ...