326
VCF fabric configuration task list
Tasks at a glance
(Required.)
Enabling VCF fabric topology discovery
Configuring automated underlay network provisioning
Configuring automated overlay network deployment
Enabling VCF fabric topology discovery
Configuration restrictions and guidelines
VCF fabric topology discovery can be automatically enabled by executing configurations in the
template file or be manually enabled at the CLI. The device uses LLDP to collect topology data of
directly-connected devices. Make sure you have enabled LLDP on the device before you manually
enable VCF fabric topology discovery.
Configuration procedure
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable LLDP globally.
lldp global enable
By default, LLDP is disabled
globally.
3.
Enable VCF fabric topology
discovery.
vcf-fabric topology enable
By default, VCF fabric topology
discovery is disabled.
Configuring automated underlay network
provisioning
Configuration restrictions and guidelines
When you configure automated underlay network provisioning, follow these restrictions and
guidelines:
•
Automated underlay network configuration can be automatically completed after the device
starts up. If you need to change the automated underlay network provision on a running device,
you can download the new template file through TFTP. Then, execute the
vcf-fabric underlay
autoconfigure
command to manually specify the template file on the device.
•
As a best practice, do not modify the network type or the device role while the device is running.
If it is necessary to do so, make sure you understand the impacts on the network and services.
•
If you change the role of the device, the new role takes effect after the device restarts up.
Summary of Contents for FlexNetwork 10500 SERIES
Page 224: ...213 ...
Page 311: ...300 Now the system can record log information to the specified file ...