No display on the configuration terminal
Symptom
The configuration terminal has no display when the switch is powered on
Action
1. Verify that the power system is operating correctly.
2. Verify that the switch is operating correctly.
3. Verify that the console cable has been connected correctly.
4. Verify that the following settings are configured for the terminal:
Setting
Value
Baud rate
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
5. Verify that the console cable is not faulty.
6. If the problem persists, contact Hewlett Packard Enterprise Support.
Garbled display on the configuration terminal
Symptom
The configuration terminal displays garbled text.
Action
1. Verify that the following settings are configured for the terminal:
Setting
Value
Baud rate
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
2. If the problem persists, contact Hewlett Packard Enterprise Support.