It is the responsibility of the installer to follow all local and State Codes concerning the installation and operation 

of the fire pit. 

 

 

SELECTING THE LOCATION 

 

WARNING: 

FIRE PITS ARE DESIGNED STRICTLY FOR

 OUTDOOR USE ONLY. 

 

        HEARTH PRODUCTS CONTROLS CO.

 MUST BE NOTIFIED OF ANY OTHER USE. 

 
WARNING: 

FIRE PITS CREATE VERY HIGH TEMPERATURES- IT IS VERY IMPORTANT THAT COMBUSTIBLES 

BE KEPT AT SAFE DISTANCES. LP CYLINDERS NOT CONNECTED TO THIS DEVICE MUST BE STORED AWAY 
FROM FIRE PIT.

 

 

 

The fire pit location must accommodate a gas shut off within 

4 feet

 of the fire pit. Gas shut off must be outside of fire 

pit. The gas line should be sized minimum gas pressure at maximum flow rate (Btu/hr).

 

 

To enjoy your fire pit, select a well drained location that allows for sufficient clearance from combustible materials.  

 

 

Choose a location that allows easy access for installation and maintenance of the fire pit. Make sure that trees and 
shrubbery are well clear around and above the fire pit.  

 

 

Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the heat 
and flame.

 

 

Select a location where the fire pit can be attended during operation.  Never leave an operating fire pit unattended or by 
someone not familiar with its operation or emergency shut off locations.

 

 

Fire Pit Clearances 

Sides Surrounding Fire Pit          14” 

        

          Above Fire Pit                             96” 

 
        INSTALLATION OF THE COMPLETE FIRE PIT 

 

1) Remove fire pit from packaging material. 

 

2) Mount valve box in preferred location. 
3) Place fire pit in enclosure. 

 

4) Connect gas supply line as outlined in Gas Supply Connection section below. 
5) Carefully fill pan with lava rock- leave air box window open to allow fresh air in- as 
    shown to the right. 

 
 
 

GAS SUPPLY CONNECTION: 
Use only gas type indicated. If the gas type indicated is not your type of gas supply, DO NOT INSTALL. Contact your 
dealer for the proper model. All piping must comply with local codes and ordinances or with the National Fuel Gas 
Code, whichever applies.

   

     The gas supply line must be of adequate size to handle the Btu/HR requirements and length of run for this fire pit. 
     The normal gas connection at this log set is ½” NPT made at the right of the unit.

 

                                                                         

 

 
    

 1) Attach and tighten flex line to the gas supply line. Confirm gas type. 

     2) If using an LP bottle, position at safe distance away from flame.  
 

 

 

 

IMPORTANT: TESTING FOR LEAKS:

 USE SOAPY WATER AT EVERY CONNECTING POINT IN GAS 

LINE. IF BUBBLES APPEAR, TURN OFF GAS, REPAIR LEAKS AND TEST AGAIN.  DO NOT LEAVE FIRE 
PIT BURNING UNTIL ALL LEAKS ARE ELIMINATED.

 NEVER USE A FLAME TO CHECK FOR LEAKS.

 

 

 

 

 

 

 

 

 

812-1   

 

 

 

 

 

 

 

 

 

 

 

Pg. 2 

 
 