background image

 

 

HPE StoreFabric CN1100R Dual Port 
Converged Network Adapter 

User Guide 

 

Abstract 

This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise 

assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy 

levels. 

Part Number: 728508-002R 

November 2015 

Edition: 3 

Summary of Contents for StoreFabric CN1100R

Page 1: ...or the person who installs administers and troubleshoots servers and storage systems Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 728508 002R November 2015 Edition 3 ...

Page 2: ...e set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other ...

Page 3: ...ental specifications 13 General specifications 13 Media specifications 13 Cable specifications 14 Compliance 14 Hewlett Packard Enterprise product QuickSpecs 15 Electrostatic discharge 16 Preventing electrostatic discharge 16 Grounding methods to prevent electrostatic discharge 16 Warranty and regulatory information 17 Warranty information 17 Regulatory information 17 Safety and regulatory complia...

Page 4: ...plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times Unplug the power cord from the power supply to disconnect power to the equipment Do not route the power cord where it can be walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extend...

Page 5: ... x8 PCIe bus slot WARNING Disconnect the host from the power source before installing the CNA Recording reference numbers The CNA ships with the IEEE address Port 1 MAC address clearly marked on the board The MAC address is a unique 48 bit identifier for configuring the system The Fibre Channel industry uses the WWN derived from the MAC address for Fibre Channel connectivity The MAC addresses are ...

Page 6: ... in the following table Item LED indicator Status Description 1 Activity Off No network activity exists on the link Blinking green Network activity is on the link The CNA is sending or receiving network data at up to 10 Gb s 2 Link Off No link to the adapter is established The CNA is not receiving power or the cable connection is faulty On orange A link to the CNA is established at 10 Gb s The CNA...

Page 7: ...lling a low profile bracket for a CNA on page 7 4 Insert and firmly seat the CNA in the PCI Express slot 5 Secure the CNA mounting bracket to the case with the panel clip or screw 6 Re install the server case and then plug in the power cord The CNA is installed in the server and ready for media attachment Installing a low profile bracket for a CNA Change the bracket if the server requires a differ...

Page 8: ... the CNA transceiver cage assembly pull the bail handle out and down to release the latch 2 Gently pull the SFP transceiver out Store the transceiver in an ESD safe place 3 Using a correctly sized slotted screwdriver carefully remove the two board lock screws located at the top and bottom of the connector ...

Page 9: ...rly aligned with the holes in the bracket 6 Install the screws that attach the CNA to the bracket Attaching media Connect the CNA with either removable SFP optical transceivers or copper interface cables Connecting the fiber optic cable 1 Insert the transceiver into the cage Be sure that the tab on the plug clicks into position 2 Connect one end of the fiber optic cable to the LC connector on the ...

Page 10: ...2 Connect one end of the copper cable to the CNA 3 Connect the other end of the cable to the converged network switch For more information see Cable specifications on page 14 Powering up the CNA 1 Verify that the CNA is securely installed in the server and that the correct media is attached 2 Plug in and power up the server 3 Observe the link and activity LEDs to be sure the CNA connects to the sw...

Page 11: ...Installing an adapter 11 4 Watch the server console for any POST error messages and the CNA for the correct BIOS startup message ...

Page 12: ... Guide http www hpe com support FCoE_Config_UG_en To perform a Boot from SAN installation over FCoE see the HPE Boot from SAN Configuration Guide http www hpe com info sandesignguide To perform an iSCSI boot see the Broadcom iSCSI Boot for HPE FlexFabric Adapters User Guide http www hpe com support iSCSI_Boot_UG_en Installing multi pathing software Multi pathing software is optional To install mul...

Page 13: ...r port 20 Gb s combined full duplex PICe slot requirements PCI Express x8 Gen2 1 Agency approvals Safety US Canada Europe EMI and EMC Class A US Canada Europe Australia New Zealand Japan Korea Taiwan Media specifications Copper cables and SFP Ethernet optical modules SR Part number SFP active copper cables for HPE B series FCoE converged network switches 1m B series active copper SFP cable AP818A ...

Page 14: ...able AJ837A 30 m LC LC multi mode OM3 Fibre Channel cable AJ838A 50 m LC LC multi mode OM3 Fibre Channel cable AJ839A For more information about support of specific cables see the product release notes Cable specifications Cable Maximum length Minimum length Connector Fiber optic cable Short range LC LC multi mode OM3 50 125 duplex 100 meters 328 08 ft 1 meter LC Copper cable 10GbE direct attach c...

Page 15: ...ion 3 0 SNMP IPv4 TCP and UDP Checksum Offload IPv4 IPv6 TCP Large Send Offload Receive Side Scaling Jumbo Frames up to 9000 Bytes Hewlett Packard Enterprise product QuickSpecs For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterprise http www hpe com info qs website ...

Page 16: ...tic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance ...

Page 17: ...ory information Safety and regulatory compliance For important safety environmental and regulatory information see Safety and Compliance Information for Server Storage Power Networking and Rack Products available at the Hewlett Packard Enterprise website http www hpe com support Safety Compliance EnterpriseProducts Belarus Kazakhstan Russia marking Manufacturer and Local Representative Information...

Page 18: ...dicates the year counting from within each new decade with 2000 as the starting point for example 238 2 for 2002 and 38 for the week of September 9 In addition 2010 is indicated by 0 2011 by 1 2012 by 2 2013 by 3 and so forth YYWW where YY indicates the year using a base year of 2000 for example 0238 02 for 2002 and 38 for the week of September 9 Turkey RoHS material content declaration Ukraine Ro...

Page 19: ...cumentation to identify the recommended software update method To download product updates go to either of the following o Hewlett Packard Enterprise Support Center Get connected with updates page http www hpe com support e updates o Software Depot website http www hpe com support softwaredepot To view and update your entitlements and to link your contracts and warranties with your profile go to t...

Page 20: ...hat an authorized service provider replace the part These parts are identified as No in the Illustrated Parts Catalog Based on availability and where geography permits CSR parts will be shipped for next business day delivery Same day or four hour delivery may be offered at an additional charge where geography permits If assistance is required you can call the Hewlett Packard Enterprise Support Cen...

Page 21: ...rd consultez le site Web Hewlett Packard Enterprise http www hpe com support selfrepair Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose i prodotti Hewlett Packard Enterprise sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente CSR Customer Self Repair Se in fas...

Page 22: ...zeichnet CSR Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar Wenn Sie Hilfe benötigen können Sie das Hewlett Packard Enterprise Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen Den Materialien von H...

Page 23: ... cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio Para obtener más información acerca del programa de Reparaciones del propio cliente de Hewlett Packard Enterprise póngase en contacto con su proveedor de servicios local Si está interesado en el programa para Norteamérica visite la página web de Hewlett Packard Ent...

Page 24: ... obra do serviço Opcional Peças cujo reparo feito pelo cliente é opcional Essas peças também são projetadas para o reparo feito pelo cliente No entanto se desejar que a Hewlett Packard Enterprise as substitua pode haver ou não a cobrança de taxa adicional dependendo do tipo de serviço de garantia destinado ao produto OBSERVAÇÃO Algumas peças da Hewlett Packard Enterprise não são projetadas para o ...

Page 25: ...Support and other resources 25 ...

Page 26: ...Support and other resources 26 ...

Page 27: ...Support and other resources 27 ...

Page 28: ...atic secure submission of hardware event notifications to Hewlett Packard Enterprise which will initiate a fast and accurate resolution based on your product s service level Hewlett Packard Enterprise strongly recommends that you register your device for remote support For more information and device support details go to the Insight Remote Support website http www hpe com info insightremotesuppor...

Page 29: ...é Européenne European Conformity CN converged network CNA Converged Network Adaptor CSA Canadian Standards Association DSM Distributed State Machine ESD electrostatic discharge FCF Fibre Channel Forwarder FCoE Fibre Channel over Ethernet IPv4 Internet Protocol version 4 IPv6 Internet Protocol version 6 iSCSI Internet Small Computer System Interface ...

Page 30: ...ponent Interconnect Express PCI X peripheral component interconnect extended PHY physical layer device POST Power On Self Test RoHS Restriction of Hazardous Substances RPM Red Hat Package Manager SFP small form factor pluggable SFP enhanced small form factor pluggable SPOCK Single Point of Connectivity Knowledge UDP User Datagram Protocol UTP unshielded twisted pair ...

Page 31: ...Acronyms and abbreviations 31 WWN World Wide Name ...

Page 32: ...tion send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hpe com When submitting your feedback include the document title part number edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices page ...

Reviews: