5.
To synchronize the time and date with the computer running the browser, click
Now
.
6.
Click
Submit
.
Enabling SNTP (Simple Network Time Protocol) synchronization
The library must have network access to an SNTP server to use this feature.
Procedure
1.
Navigate to the
System > Date and Time Format
screen.
2.
Click
SNTP
.
3.
Click
SNTP Enabled
.
4.
Enter the SNTP server address.
5.
Click
Submit
.
Configuring media barcode compatibility checking
When Barcode Media ID Restriction is enabled, the library will only allow appropriate data cartridges to be
loaded into tape drives. The barcode media ID is the last two characters of the barcode. For example, the
library will not move an LTO-6 labeled cartridge into an LTO-4 tape drive.
When disabled, the library will move any data cartridges to any tape drive. If the cartridge is incompatible
with the tape drive, the library displays a message.
NOTE:
Barcode labels are recommended on all cartridges in the library. For efficient operation, include the
correct media ID on the label and keep the Barcode Media ID Restriction option enabled (the default
setting).
Procedure
•
Enable media barcode compatibility checking
•
Disable media barcode compatibility checking
Enabling media barcode compatibility checking
When media barcode compatibility checking is enabled, the library will only allow appropriate data
cartridges to be loaded into tape drives.
The barcode media ID is the last two characters of the barcode. For example, the library will not move an
LTO-6 labeled cartridge into an LTO-4 tape drive.
When disabled, the library will move any data cartridges to any tape drive. If the cartridge is incompatible
with the tape drive, the library displays a message.
Procedure
1.
Navigate to the
Configuration > System > Media Barcode Compatibility Check
screen.
2.
Click
Barcode Media ID Restriction
.
3.
Click
Submit
.
60
Enabling SNTP (Simple Network Time Protocol) synchronization