If a parking position is not selected within 10 seconds, the library will park the robotic assembly in this
location.
•
The shipping position
—With this option the robotic assembly will move to the bottom of the base
module above the bottom cover. Select this option when the base module will be removed from the
rack for shipping or when the base module is the bottom module in a library that is shipping in a rack.
IMPORTANT:
Only select this option when the base module has a bottom cover.
Before moving or shipping a library, see
LED indicators
UID
Blue when activated. The unit identification (UID) LEDs are controlled by the user through
the OCP
Operations > UID LED Control
screen and RMI
Maintenance > UID LED
Control
screen. The UIDs on the OCP and back panel are activated and deactivated
together. The UIDs are helpful for locating the library in a data center.
Ready
Green, steady when power is on, blinking with tape drive or library robotic activity.
Clean
Amber when a tape drive cleaning operation is recommended.
Attention
Amber if the library has detected a condition for which user attention is necessary, but the
library can still perform most operations.
Error
Amber if an unrecoverable tape drive or library error occurs. A corresponding error message
is displayed on the LCD screen. User intervention is required; the library is not capable of
performing some operations.
MSL3040 OCP menu
• Initial Setup
• Operation
◦ Move Media
◦ Move Cartridge from Drive to Home Slot
◦ Inventory Scan
◦ UID LED Control
• Configuration
◦ Date & Time
◦ Network Settings
◦ Drive Power On/Off
◦ User Accounts
48
MSL3040 OCP menu