Table 5 Known issues
(continued)
Resolution
Issue
d.
create partition msr size=128
e.
exit
3.
Enter the
Get-partition –DiskNumber <disk number from above>
command to verify the new partitions.
To register SMI-S provider with the HP StoreEasy 3000 Storage, ensure that the
array is reachable from the node. Perform the following steps on all nodes:
The SMI-S provider registration with
HP StoreEasy 3000 Storage might
fail due to the following reasons:
1.
Open an elevated PowerShell command prompt.
•
No network connectivity existing
between the array and node.
2.
Enter the following commands for HTTP and HTTPs SMI-S provider:
a.
Register-SmisProvider -ConnectionUri
http://<ipadress>:<port-no>
.
•
Array is SMI-S provider listing
on port other than the default
HTTPS port (5989).
NOTE:
For HTTPs port SMI-S provider, enter
Register-SmisProvider
-ConnectionUri https://<ipadress>:<port-no>
.
b.
Update-StorageProviderCache -DiscoveryLevel 3 -PassThru
.
3.
Enter
Get-StorageProvider
to verify the registration of SMI-S provider.
If the registration is successful, SMI-S provider is displayed as registered on
the system.
Error codes
This section contains the error codes that may occur.
HP Insight Management CSP WBEM Providers for Windows error codes
The HP Insight Management CSP WBEM Providers for Windows error codes are listed in
.
Table 6 HP Insight Management CSP WBEM Providers for Windows errors
Resolution
Event Log Entry
Type
Source
Description
Error
code
Retry query to provider after 3 minutes.
Informational
HP CSP WBEM
Providers
The CSP Enclosure Provider is
initializing.
0x910
Success
HP CSP WBEM
Providers
CSP Enclosure Provider
initialization successful.
0x911
Check EM connections and retry query to
provider after 3 minutes.
Warning
HP CSP WBEM
Providers
Enclosure Provider lost connection
with EM.
Fan, Power supply and IO/PCIe
Modules classes will not work.
0x912
Check the provider logs for details. Retry
query to provider after 3 minutes.
Warning
HP CSP WBEM
Providers
Enclosure Provider is unable to
parse the input data provided by
EM.
Fan, Power supply and IO/PCIe
Module classes will not work.
0x913
Blade classes may give only partial
data.
Check the provider logs for details.
Warning
HP CSP WBEM
Providers
Enclosure Provider is unable to
build internal lists using data
provided by EM.
0x914
Check the provider logs for details.
Error
HP CSP WBEM
Providers
Enclosure provider is not
recongising this blade server.
Many or all the classes may fail.
0x915
Error codes
83