![HP StorageWorks Series Quick Start Manual Download Page 4](http://html.mh-extra.com/html/hp/storageworks-series/storageworks-series_quick-start-manual_159701004.webp)
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT
/
LNK
ACT
/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT
/
LNK
PORT 1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
PORT
0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
PO
RT 2
FIBRE
CHANNEL
T/
K
ACT/
LNK
ACT/
LNK
PORT
1
PORT
0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
PO
RT 2
FIBRE
CHANNEL
T/
K
ACT
/
LNK
ACT
/
LNK
PORT 1
PORT 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT
/
LNK
ACT
/
LNK
PORT 1
PORT 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT
/
LNK
ACT
/
LNK
PORT 1
PORT 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT
/
LNK
ACT
/
LNK
PORT 1
PORT 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT
/
LNK
ACT
/
LNK
PORT 1
PORT 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT
/
LNK
ACT
/
LNK
PORT 1
PORT 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
ACT/
LNK
ACT/
LNK
PORT
1
POR
T 0
ETHERNET
SERIAL
PWR
FIBRE
CHANNEL
FIBRE
CHANNEL
Remove the e1200-160
robotics controller card
19
20
15
16
17
18
Label and disconnect the cables attached to the
robotics controller card.
Use a #2 Phillips screwdriver to loosen the
captive screws in the black ejector handles at
both ends of the robotics controller. Push the
ejector handles toward the outside, then pull on
them to remove the controller.
Using a #2 Phillips screwdriver, remove the 4
screws securing the metal spacer to the bottom of
the card cage.
Using a #2 Phillips screwdriver, remove the
1 screw on the front of the metal spacer directly
to the left of the e1200-160.
From the card cage, remove the metal spacer
and the metal plate associated with the spacer.
Using a razor or scraper, remove the rubber gasket
from the right side of the bottom of the robotics
controller slot. Use isopropyl alcohol to clean any
residue left on the card cage from the rubber gasket.