Firmware Revision — version of the currently installed drive firmware.
•
SCSI ID (parallel SCSI drive only) — SCSI address of the drive. The LUN for the tape drive is 0.
If a drive is removed or powered off, its number will be reserved. If a drive is added between two
other drives, it is assigned the next available number. The drive numbers are persistent until the
factory defaults are restored or the Library is power cycled.
•
World Wide ID (SAS drive only) — world wide unique name for the drive. The World Wide ID
is assigned by the library controller to the drive bay and cannot be changed by the user. When
a tape drive is replaced, the World Wide ID is re-assigned to the replacement drive.
•
Physical Drive Slot Number — the physical location of the drive. By default, the drives are numbered
from the bottom of the device up, starting with number 1.
•
SCSI Element Address (parallel SCSI or SAS drive) or Element Address (FC drive) — element ad-
dress. The SCSI Element Address is set at the factory and can only be configured by a host applic-
ation.
•
Library LUN Hosted by Drive — Yes, if this drive is hosting the Library at LUN 1.
•
Data Compression — Yes, if the host has hardware compression turned on for the drive.
•
Interface Type — SCSI, Fibre Channel, or SAS
•
WWide Node Name (FC drive only) — world wide unique number for the drive. The Library assigns
WWNames to the drive bays. When a tape drive is replaced, the WWName is re-assigned to
the replacement drive.
•
Port information for each configured port (FC drive only)
• WWide Port Name — world wide unique identifier for the port. The WW Node and Port
Name will be slightly different.
• Port Type — the current setting of the drive port. Direct connected devices are typically Loop.
Devices connected to a switch are typically Fabric.
• Speed
Viewing network information
The
displays information about the network configuration.
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
guide
75
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...