Restore defaults (Configuration > Restore Defaults)
This option returns the Library to its original shipping configuration, leaving the settings necessary for
the RMI. Access to this feature requires the administrator password.
The following settings are reset:
•
SCSI addresses:
• MSL4048: For full-height tape drives the default SCSI address is 4. For half-height drives, the
default SCSI address for the bottom drive in each full-height drive bay is 4 and the default
SCSI address for the top drive is 5 as shown in
.
Figure 88 MSL4048 parallel SCSI tape drive default SCSI addresses
.
1. Tape drives with SCSI address 4
2. Tape drives with SCSI address 5
• MSL8048 and MSL8096: The default SCSI address for all tape drives is 4.
The Library will no longer recall drives that have been removed.
•
Master drive: reset to Drive 1 or the lowest numbered existing drive
•
Drive power: all drives powered on
•
Active slots: maximum possible
•
Library mode: Automatic
•
Loop: No
•
Event log levels and filter: continuous trace and all levels and filters active (for HP Service use only)
•
Barcode reader label length: 8
•
Barcode reader alignment: Left
•
Error recovery: On
•
Mailslot configuration: mailslot disabled
•
Auto clean: disabled
•
SNMP: disabled, but saved addresses do not change
•
E-mail notification: disabled, but configurations retained
The following settings are not reset:
•
Administrator password
•
Network settings (network is always enabled and the network addresses are retained)
•
Date and time
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
guide
145
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...