HP

StorageWorks

6000 Virtual

Library System

Disk Array

Installation

Rack requirements:

HP supports the HP System E racks and the
HP 10000 Series racks for use with the virtual
library system (VLS). Other racks might also be
suitable, but have not been tested with the VLS.

Caution:

Make sure that the rack and all

equipment mounted in the rack has a
reliable ground connection. Verify that the
total current of the rack components does
not exceed the current rating of the power
distribution unit or outlet receptacles.

Caution:

Parts can be damaged by

electrostatic discharge.  Keep parts in their
containers until needed.  Ensure that you
are properly grounded when touching 
static sensitive components.  

1

Inspect the box contents.
You will also need a
Phillips screwdriver.

Warning:

The MSA20 disk array

weighs 24 kg (53 lb) full. At least two
people are required to lift and rack mount
the disk array. 

Warning:

To reduce the risk of personal

injury or damage to the equipment, before
installing equipment be sure that:

The rack leveling jacks are extended to

the floor.

The full weight of the rack rests on the

leveling jacks.

The stabilizing feet are attached to the

rack if it is a single-rack installation.

The racks are coupled together in

multiple-rack installations.

Only one component is extended at a

time. A rack may become unstable if
more than one component is extended
for any reason.

1 MSA20 disk array
2 SCSI cable
3 Printed VLS disk array

installation poster

4 Disk array power cords (2)
5 2U rack mounting hardware kit

Summary of Contents for StorageWorks MSA20

Page 1: ...rounded when touching static sensitive components 1 Inspect the box contents You will also need a Phillips screwdriver Warning The MSA20 disk array weighs 24 kg 53 lb full At least two people are required to lift and rack mount the disk array Warning To reduce the risk of personal injury or damage to the equipment before installing equipment be sure that The rack leveling jacks are extended to the...

Page 2: ...assword 3 Initiate a shutdown of the VLS by entering shutdownSystem and then press Enter 4 When the VLS has completed its shutdown operation press the node Power On Standby button to place the node in standby mode When the node activates standby power mode the system power LED changes to amber 2 If you are installing a capacity bundle or an existing disk array to the VLS base configuration install...

Page 3: ...ide to the required location of the locking latches in this case Warning The pins in the rails are load bearing Do not remove the pins except to replace them with the pins for round hole racks 6 If the holes in the rack uprights are round instead of square remove the standard pins from the rails and replace them with the round hole pins provided in the rack mounting hardware kit Identify the left ...

Page 4: ...onnector on the node as shown 1 VHDCI connector A1 connect to disk array 1 2 VHDCI connector A2 connect to disk array 2 3 VHDCI connector B1 connect to disk array 3 4 VHDCI connector B2 connect to disk array 4 9 Align the disk array with the rails and slide it into the rack 1 2 10 Remove the mounting bracket covers and tighten the thumbscrews to secure the disk array to the rack Replace the mounti...

Reviews: