Figure 26 I/O tab of Disk Enclosure Properties window
NOTE:
The Firmware revision fields are different for EVAx400 and P6000 disk
enclosures.
If the fields Assembly serial number, Hardware revision, and Hardware type on the I/O
tab of the Disk Enclosure Properties window are blank, you can optionally reset the I/O
modules to clear the blank fields after the I/O module firmware upgrade has completed
successfully. Note that blank fields do not affect the array's ability to process host I/O.
See
“Resetting the I/O module” (page 55)
for more information.
e.
Check the operational states that you recorded and proceed as follows:
•
Good: No action
•
Loading firmware: The I/O module firmware load is blocked. Corrective action is
required somewhere on the array (but not on this I/O module). Continue with
Step
18
•
Any state other than Good or Loading firmware: Corrective action is required on
this I/O module. Continue with
Step 18
.
18. Check the event log for the code-load-blocked code (
066df308
, critical event). If you do not
see this event, contact your HP-authorized service representative for assistance. If you see this
event, continue with
Step 19
.
54
Upgrading the Enterprise Virtual Array