Setting the SCSI ID

Each SCSI device attached to the server that is to be the host 
for the DLT VS 40/80 GB tape drive must have a unique SCSI 
ID. Check the SCSI IDs on all other devices attached to the 
selected SCSI bus, including the SCSI host adapter itself, on 
the selected server and select an unused SCSI ID for the tape 
drive. If the drive factory default SCSI ID 6 is not being used 
by another device on the same SCSI bus, you do not need to 
change the SCSI ID.

Figure 1:  Rear view of internal tape drive

1

68-pin SCSI connector

2

Power connector

3

SCSI ID jumpers

Note:  

If the tape drive is attached to a narrow SCSI bus, only IDs 0 

through 7 are valid.

Locate the SCSI ID jumpers on the rear panel of the drive as 
shown in Figure 1. Use Figure 2 to select the desired SCSI ID.

Figure 2:  SCSI ID settings

Note:  

The SCSI ID can be set up to 15, but a SCSI ID above 6 is not 

recommended.

Note:  

SCSI ID 7 is reserved for the controller.

Terminating the Tape Drive

If the DLT VS 40/80 GB tape drive is the only SCSI device – 
other than the SCSI host adapter – on the selected server, it 
must be terminated. Likewise, if the DLT VS 40/80 GB tape 
drive is the last device on the selected server SCSI bus, it must 
be terminated.

The DLT VS 40/80 GB tape drive ships with a ribbon cable 
that is already terminated as shown in Figure 3. If you use a 
cable other than the one provided, be sure that the cable is 
terminated at each end.

Figure 3:  Ribbon cable with terminator

Installing the Internal Tape Drive

Caution:  

Electrostatic discharge (ESD) can damage 

electronic components. Be sure you are properly grounded 

before beginning this procedure. Refer to Appendix B, 

“Electrostatic Discharge,” in the 

HP StorageWorks DLT VS 

40/80 GB Tape Drive Reference Guide

 for additional 

information.

1. Shut down the operating system and power off the selected 

server. Turn off all attached peripherals such as printers and 
other SCSI devices. Remove the power cable from the host 
server and all attached peripherals.

Caution:  

Failure to follow these instructions could result in 

damage to the DLT VS 40/80 GB tape drive or other 

devices.

2. Remove the cover from the host server to allow access to 

the desired drive bay.

Note:  

Your server may differ from the following illustrations; refer to 

the documentation included with your server.

1

2

3

SCSI ID

0

1

2

3

4

5

6

Jumper

Block