Workaround prior to upgrade:
Do not
enable Top Talkers concurrently with
functionality that is using frame
redirection.
Fixed in Fabric OS 6.2.0c
When Top Talkers is enabled with frame redirection, HP StorageWorks
DC SAN Director can crash causing data encryption backup to fail.
Fixed in Fabric OS 6.2.0c
Stable working encryption group experienced a split after successful
I/O test run, and encryption group leader got a
comm
error.
Fixed in Fabric OS 6.2.0c
Encryption group does not automatically recover after encountering a
split group condition.
Workaround prior to upgrade:
1.
Disable the target ports. 2. Remove
one initiator from the container. 3.
Start the rekey operation. 4. Add the
initiator back.
Fixed in Fabric OS 6.2.0c
When performing first time encryption to a LUN with more than one
initiator active at the same time, rekey operations slow significantly,
causing host applications to experience delays in the completion of
I/O requests.
Fixed in Fabric OS 6.2.0c
Software verify errors and IFCCs occurred during
supportsave
on
HP StorageWorks DC SAN Director and on HP StorageWorks DC04
SAN Director
Fixed in Fabric OS 6.2.0c
Chassisinfo is not provided with snmpv1 without adding and configur-
ing an snmpv3 user. The first 6 objects in the system MIB are missing,
corresponding to the
Error: no such object
entries in the Hi-
Track system table.
Fixed in Fabric OS 6.2.0c
VIs/VTs may disappear when rebooting the HP StorageWorks Encryp-
tion SAN Switch that has all physical connections to targets and initi-
ators.
Fixed in Fabric OS 6.2.0c
Repeatedly disconnecting and reconnecting ISL links between the HP
StorageWorks Encryption SAN Switch in an HA cluster environment
while rekey operations are in progress may cause data miscompare.
Fixed in Fabric OS 6.2.0c
Internal recovery scheme can attempt to correct a valid Frame Redirec-
tion RAM Filter, which can lead to one existing filter being corrupted,
potentially causing misrouted frames. This is a very rare occurrence.
Fixed in Fabric OS 6.2.0c
Running
configdefault
may cause kernel panic on an HP Storage-
Works 4/256 SAN Director.
Fixed in Fabric OS 6.2.0c
An unexpected switch panic can occur when
supportsave
reads
invalid data on GE ports without FC Fast Write enabled.
Fixed in Fabric OS 6.2.0c
FICON XRC times out on a 400 MP Router to an HP DC SAN Director,
which causes drives not to come online.
Enabled new SFP support in Fabric
OS 6.2.0c
Need support in Fabric OS for DWDM-SFP media.
Fixed in Fabric OS 6.2.0c
HP StorageWorks 8/40 SAN Switch did not indicate a warning when
a PS/FAN FRU was removed.
Fixed in Fabric OS 6.2.0c
High temperature alerts are reported on an HP StorageWorks DC
Switch Encryption Blade when the ambient temperature is 39
o
Celsius.
HP StorageWorks Fabric OS 6.2.0g release notes