Sizing Guidelines: For Exchange environments, AiO1200 SATA

configurations are appropriate for storage groups with less than 500

mailboxes while AiO1200 SAS configurations support up to 1,500

mailboxes when using the Exchange ESRP implementation guidelines.

Out of the box implementations for the AiO1200 will support approx

25% of these numbers. The AiO1200 is certified with VMWare ESX

for iSCSI connectivity; due to the highly random read/write

performance characteristics of VMFS we recommend SAS HDDs for

use with VMWare ESX and VMFS.

HP StorageWorks All-in-

One SB600c Storage

Blade (AiO SB600c)

This half-height all-in-one storage blade solution was designed for HP c-class

BladeSystem environments and combines a BL460 server blade and SB40

storage blade. It provides shared storage expansion for blade servers (iSCSI

SAN), enhanced file serving for end-user clients (NAS), and comprehensive

data protection features. The AiO SB600c is an excellent solution for

customers looking at c-3000 or c-7000 BladeSystem deployments. The AiO

SB600c is available in a SAS configuration.

Sizing Guidelines: For Exchange environments, AiO SB600c SAS

configurations are appropriate for storage groups with less than 500

mailboxes. The AiO SB600c is certified with VMWare ESX for iSCSI

connectivity.

Software Feature

Specifications for the

HP All-in-One Storage

Family

All-in-One Storage

Management

Interface

This single easy to use, integrated storage management tool can manage many

aspects of the storage environment.

Rapid startup tools for fast and easy installation and out-of-the box

configuration

Provides end-to-end management and provisioning of iSCSI storage for non-

clustered 32-bit and 64-bit Windows Server 2003 hosts from the iSCSI

Target all the way through to the host

Provides management and provisioning of iSCSI storage for standards-

compliant non-Windows iSCSI initiators such as VMWare, Linux, etc.

Application data hosting and migration wizard using HP and Microsoft 'Best

Practice' storage configurations for Microsoft Exchange 2003/2007

Storage Groups and Microsoft SQL Server 2000/2005 databases.

Application data hosting and iSCSI Setup wizard for other 'User Defined'

Applications (Oracle, mySQL, VMware ESX, etc.)

File Share creation wizard with storage allocation and directory quota

management.

Data protection policy assignment (snapshots and backup) integrated into

application migration and share creation wizards for data hosted on the

system.

Data Protector Express virtual library device provisioning and space

management as well as support for Data Protector Express D2D2Any add-on

option.

Application-level capacity provisioning and online growth for shares, SQL

Server and Exchange. SQL Server support includes data file and log

directory provisioning and Exchange support includes Mailstore, Publicstore

and log directory provisioning.

Quota monitoring and alerting per share or application.

Remote management via Microsoft Internet Explorer or Terminal Services.

Support for iLO or Lights-Out 100 varies by platform.

Support for setup and management of both internal storage as well as

supported direct attached MSA storage enclosures.

Supports management of tiered storage environments where both SAS,

parallel SCSI, or SATA hard drives are attached to the All-in-One Storage

System either internally or on externally attached MSA storage enclosures.

Shared Application

Storage (Microsoft

iSCSI Software

Target)

Compliant with iSCSI industry standards and compatible with industry

standard iSCSI initiators. Interoperability has been verified for Windows

2000, Windows Server 2003, VMware ESX Server 3, SUSE Linux

Enterprise Server 10, RedHat Enterprise Linux 5, and Qlogic 40xx series

iSCSI hardware HBAs. For additional information please visit:

QuickSpecs

HP StorageWorks 400t and 400r All-in-One

Storage Systems

Highlights

DA - 12913   Worldwide QuickSpecs — Version 1 — 2.11.2008

Page 4

Summary of Contents for StorageWorks 400r All-in-One

Page 1: ...ovides many of the management consolidation and data protection features typically reserved for higher priced and more complex storage products NOTE iSCSI performance varies by model and host application I O characteristics For best performance choose a system with a high number of drive spindles and utilize SAS hard drives About the AiO400t This 4 drive entry level tower solution built on the Pro...

Page 2: ...ks saving you time and reducing the risk to your business Shared storage for growing application servers iSCSI SAN enables efficient use of capacity Sharing storage between servers is more efficient and costs less to manage over time when compared against adding additional drives to individual servers Sharing storage means that you maximize investments in additional capacity while enabling easier ...

Page 3: ...n 100 mailboxes when using the Exchange ESRP implementation guidelines Out of the box implementations should only use the AiO400 for very few users or archival Storage Groups unless using SAS HDDs While it is certified for VMWare ESX iSCSI connectivity the AiO400 is not recommended in VMFS environments due highly random read write performance characteristics of VMFS HP StorageWorks 600 All in One ...

Page 4: ...iant non Windows iSCSI initiators such as VMWare Linux etc Application data hosting and migration wizard using HP and Microsoft Best Practice storage configurations for Microsoft Exchange 2003 2007 Storage Groups and Microsoft SQL Server 2000 2005 databases Application data hosting and iSCSI Setup wizard for other User Defined Applications Oracle mySQL VMware ESX etc File Share creation wizard wit...

Page 5: ...on Integrated Data Protection RAID hard drive configurations hot swappable drives Disk based snapshots for easy roll back Scheduled or ad hoc by application Managed through HP All in One Storage Manager Exchange and SQL Server aware snapshots ensure consistent data sets for the applications 512 snapshots per independent iSCSI Application volume 64 snapshots for file share volumes NOTE If iSCSI LUN...

Page 6: ...System fan 7 Serial Ports 2 PCI slot cover retainer 8 VGA Port 3 PCI slot covers one slot occupied by Smart Array E200 and one slot occupied by 360T NIC 9 PS 2 Keyboard Port 4 HP LO 100c Management Port Optional 10 PS 2 Mouse Port 5 LAN Port RJ 45 11 Power Supply Outlet 6 Rear USB 2 0 Ports 12 Power supply unit PSU fan QuickSpecs HP StorageWorks 400t and 400r All in One Storage Systems Highlights ...

Page 7: ...CIe x8 slot occupied by Smart Array E200 128MB controller 1 Lights out 100c option slot Network Controller Embedded NC105i PCIe Gigabit Ethernet Server Adapter Additional NC360T dual port Gigabit Ethernet Server Adapter Remote Manageability Remote system management User Interface UI Remote Desktop or Telnet Remote hardware management via optional Lights Out 100 Form Factor Micro ATX Tower Power an...

Page 8: ...rm factor front load hot plug hard drives 1TB SATA Model 4 x 250GB 7 200 RPM HDDs 2TB SATA Model 4 x 500GB 7 200 RPM HDDs 1 2TB SAS Model 4 x 300GB 15 000 RPM HDDs Storage Layout Factory RAID configuration 1 RAID 5 Logical disk for OS on disks 0 3 1 RAID 5 Logical disk for DON T ERASE recovery partition on disks 0 3 1 RAID 5 Logical disk for User Data and iSCSI LUNs on disks 0 3 Optical Drive Slim...

Page 9: ...media such as tape for longer term retention Agents are available for the protection of networked file servers application servers HP Data Protection Storage Server and Windows desktops High performance is delivered through the Data Protector Express three tier architecture unique in this class of product and self tuning parallel backup streams that allows multiple jobs to run concurrently The HP ...

Page 10: ...roblems that tax user productivity HP Care Pack services help you increase IT environment stability efficiency and agility from the desktop to the data center and improve the productivity of your employees HP offers an optional migration service to assist the customer in moving to the newest product release This may be in the form of a defined kit and service or may alternatively be performed on a...

Page 11: ...e Rapid Startup Wizard which sets such things as date time user name and password setting up integrated Lights Out iLO and simple network management protocol SNMP The AiO Create a Shared Folder Wizard is run to configure the AiO to share files and access is confirmed Finally a product orientation of 10 minutes provides a brief overview of how the product was set up as well as how to find informati...

Page 12: ...rom the desktop to the data center Support Portal The HP support portal provides one stop access to the information tools and services you need to manage the daily operations of your IT environment Features include Access to self solve tools including search technical knowledge base Efficient logging and tracking of support cases Collaboration with other business and IT professionals Download of p...

Page 13: ...ge Controller Smart Array E200 128MB Controller with BBWC Internal Storage Varies by model select model below depending on needs Capacity points listed are total raw capacity Hard drives are non hot pluggable Optical Drive Half Height Internal DVD ROM Network Controller Embedded NC105i PCIe Gigabit Ethernet Server Adapter plus Additional NC360T dual port Gigabit Ethernet Server Adapter Form Factor...

Page 14: ...ote Management Remote management User Interface UI Remote Desktop or Telnet HP ProLiant Lights Out 100i remote management Advanced Pack included File Serving Protocol Support SMB CIFS NFS NCP AppleTalk HTTP FTP iSCSI Initiator Support Compliant with iSCSI industry standards and compatible with industry standard iSCSI initiators Interoperability has been verified for Windows 2000 Windows Server 200...

Page 15: ... 12566_div 12566_div html SC11Xe HBA Step 2b AiO400r options Additional Processor NOTE The AiO400r supports a total of 2 processors so you may add one additional processor if desired Quad Core Intel Xeon processor E5405 2 00GHz 80W 1333MHz FSB Option Kit 446077 B21 Additional Memory NOTE Every HP All in One 400r Storage System comes standard with 2 GB of memory and is expandable to OS limit of 4 G...

Page 16: ...Expansion 1 incremental drive LTU BB133AA Storage Mirroring replication software T5446A HP StorageWorks Storage Mirroring software enables remote replication over an IP LAN WAN between multiple All in One Storage Systems for both file NAS and block iSCSI data Key features include asynchronous replication that can be scheduled to a fine granular level Logical Unit Number LUN file or byte level Othe...

Page 17: ...o connect Please consult the EBS connectivity matrix at http www hp com go ebs for detailed connectivity information Recommended tape backup solutions for All in One Storage Systems Recommendation Lowest Cost Highest Performance Model Tape Solution 4 full backups total TB Full Backup Time in Hours Tape Solution 2 full backups total TB Full Backup Time in Hours Tape Solution 4 full backups total TB...

Page 18: ...rSys SVC UH170PE HP Installation UF285E AiO400r CarePacks HP 1y Support Plus AiO400r t StorSys SVC UH165E HP 1ySupportPlus24 AiO400r t StorSys SVC UH166E HP 3y Support Plus AiO400r t StorSys SVC UH167E HP 3ySupportPlus24 AiO400r t StorSys SVC UH168E HP 1y PWSupportPlusAiO400r t StorSys SVC UH169PE HP 1yPWSupportPlus24AiO400r tStorSys SVC UH170PE HP Installation UF285E QuickSpecs HP StorageWorks 40...

Page 19: ... 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the type and number of options installed System performance may be reduced if operating with a fan fault or above 30 C 86 F Non operating 30 to 60 C 22 ...

Page 20: ...e type and number of options installed System performance may be reduced if operating with a fan fault or above 86 F 30 C Non operating 40 to 140 F 40 to 60 C Maximum rate of change is 36 F hr 20 C hr Relative Humidity non condensing Operating 10 to 85 relative humidity Rh 82 4 F 28 C maximum wet bulb temperature non condensing Non operating 10 to 95 relative humidity Rh 101 7 F 38 7 C maximum wet...

Page 21: ...tion The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein QuickSpecs HP StorageWorks 400t and 400r All in One Storage Systems Technical Specifications DA ...