Fabric OS 6.2.0b fixes
The following table lists defects closed in the Fabric OS 6.2.0b firmware release.
Table 10 Fabric OS 6.2.0b closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.2.0b.
CUP can fail to send CU-End to clear busy. CUP is still responsive, but
the host is waiting for the CUE.
Fixed in Fabric OS 6.2.0b.
WWN card FRU replacement does not send async reports to FICON
host, so that customers do not know when a WWN card has been
removed.
Fixed in Fabric OS 6.2.0b.
Customers may experience high CPU load and unexpected blade errors
due to an ASIC-generated interrupt handling problem.
Fixed in Fabric OS 6.2.0b.
Unable to configure ports using
configdownload
if the ports are
not physically present in the director (blade not plugged in).
Workaround prior to upgrade:
Do not
change VF mode until dual CP chassis
is in sync
Fixed in Fabric OS 6.2.0b.
.
On HP StorageWorks DC SAN Director, after running
fosconfig
--enable vf
, followed by
fosconfig --disable vf
, customer
cannot log in via Telnet or serial port, and a
Cannot assign valid
AD at the login session
error occurs.
Workaround prior to upgrade:
Activate the same PDCM Matrix from
Web Tools with
Active=Save
Mode
check from
Edit CUP Port
Connectivity configuration
window.
Fixed in Fabric OS 6.2.0b.
When activating a saved PDCM Matrix from
activate CUP Port
Connectivity Configuration
dialog in Web Tools, with
Act-
ive=Save Mode
checked, Web Tools displays an error.
Workaround prior to upgrade:
The
switch name can be displayed from
Fabric OS CLI command
switchname
Fixed in Fabric OS 6.2.0b.
c-Class Onboard Administrator is unable to read the
switchname
for Brocade 8Gb SAN Switch for HP BladeSystem c-Class.
Workaround prior to upgrade:
Stop
and restart I/O may recover.
Fixed in Fabric OS 6.2.0b.
End-to-end data frames in one direction of bidirectional I/O not re-
covered after
switchdisable
and
switchenable
on a Base switch.
Fixed in Fabric OS 6.2.0b.
Unexpected software call traceback error messages occasionally being
displayed on DC04 console.
Fixed in Fabric OS 6.2.0b.
Frame drops sometimes occur when a trunk port comes online, even
with Lossless DLS feature enabled.
Fixed in Fabric OS 6.2.0b.
Interactive mode stores
supportsave
files in switch root directory
rather than the USB device, which can also result in compact flash
storage overflow.
HP StorageWorks Fabric OS 6.2.0b release notes
41
Summary of Contents for StorageWorks 4/8 - SAN Switch