HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide
45
Are both drive module LEDs off (Online/Activity and Fault/UID)?
Is the drive module Fault/UID LED blinking amber?
Is a connected host port’s Host Link Status LED off?
Answer
Possible Reasons
Actions
Yes
•
There is no power.
•
The drive is offline.
•
The drive is not configured.
•
Check that the drive is fully inserted
and latched in place, and that the
enclosure is powered on.
Answer
Possible Reasons
Actions
No, but the
Online/Activity LED
is
blinking
.
The drive is rebuilding.
No action required.
NOTE:
Do not remove a drive that is
rebuilding. Removing a drive might
terminate the current operation and
cause data loss.
Yes, and the
Online/Activity LED
is
off
.
The drive is offline. A predictive
failure alert may have been
received for this device.
•
Check the event log for specific
information regarding the fault.
•
Isolate the fault.
•
Contact an authorized service
provider for assistance.
Yes, and the
Online/Activity LED
is
blinking
.
The drive is active, but a
predictive failure alert may have
been received for this device.
•
Check the event log for specific
information regarding the fault.
•
Isolate the fault.
•
Contact an authorized service
provider for assistance.
Answer
Possible Reasons
Actions
No
System functioning properly.
No action required.
Yes
The link is down.
•
Check cable connections.
•
Reseat cables.
•
Replace cables.
•
In SMU, review the event logs for
indicators of a specific fault in a
host data path component.
Summary of Contents for StorageWorks 2324fc
Page 6: ...6 ...
Page 8: ...8 ...
Page 10: ...10 ...
Page 14: ...14 ...
Page 16: ...16 Overview ...
Page 30: ...30 Installing the enclosures ...
Page 34: ...30 Basic operation ...
Page 42: ...38 LED descriptions ...
Page 64: ...60 Parts catalog ...
Page 70: ...66 Electrostatic discharge ...