FRU Removal and Replacement
222
Factory Defaults
lists the defaults for the passwords and IP, subnet, and gateway
addresses.
Table 24: Factory-set Defaults
Procedural Notes
Note:
HAFM and Element Manager screens in this manual may not match the screens
on your server and workstation. The title bars have been removed and the fields may
contain data that does not match the data seen on your system.
The following procedural notes are referenced as applicable. The notes do not
necessarily apply to all procedures in the chapter.
1. Before performing a FRU repair, read the removal and replacement
procedures for that FRU carefully and thoroughly to familiarize yourself with
the procedures, and to reduce the possibility of problems or customer down
time.
2. When performing procedures described in this chapter, follow all electrostatic
discharge (ESD) procedures, WARNING and CAUTION statements, and
statements listed in the preface of this manual.
3. After completing the steps of a detailed procedure that is referenced from
another procedure, return to the initial (referencing) procedure and continue to
the next step of that procedure.
4. After completing a replacement procedure, clear the event code reporting the
failure and the event code reporting the recovery from the Director 2/140
Event Log (at the HAFM appliance), and extinguish the amber system error
light- emitting diode (LED) at the director front bezel.
Item
Default
Customer password
password
Maintenance password
level-2
IP address
10.1.1.10
Subnet mask
255.0.0.0
Gateway address
0.0.0.0
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...