background image

Fault Tolerance

Keeps data available and server running while a failed drive is being replaced; several fault
tolerance configurations are supported including:

RAID 6 with ADG 

(Advanced Data Guarding): This is the highest level of fault tolerance. It

allocates two sets of parity data across drives and allows simultaneous write operations.
This level of fault tolerance can withstand two simultaneous drive failures without downtime
or data loss.

RAID 5 

(Distributed Data Guarding): This allocates one set of parity data across drives and

allows simultaneous write operations. This level of fault tolerance can withstand a single
drive failure without downtime or data loss.

RAID 1, 1+0

 (Drive Mirroring): This allocates half of the drive array to data and the other half

to mirrored data, providing two copies of every file. It is a high-performance RAID.

Fault Recovery

Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure

Recovery ROM: This feature protects the user from a firmware image corruption by storing a
redundant copy of the firmware image. If the active firmware image becomes corrupt, the
controller will use the redundant firmware image and continue operating.
On-Line Spares: There is no limit to the number of spare drives that can be installed prior to
drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is
reconstructed automatically.
DRAM ECC detects and corrects data bit errors.
Battery-backed write cache upgrade provides for up to two days of battery power for data
cache retention. The data backup duration could be extended anytime the server's auxiliary
power is available during system power down.

Ease of Use

Consistency and Upgradeability make the Smart Array family unique in the industry:

GUI based configuration, management and diagnostic software tools
Common data format between generations of products
Data migration between servers and external StorageWorks Modular Smart Array
enclosures

QuickSpecs

HP Smart Array P400 Controller

Standard Features

DA - 12400   Worldwide QuickSpecs — Version 5 — 10/3/2006

Page 4

Summary of Contents for SA-P400

Page 1: ... Controller with BBWC 411064 B21 Upgrade Options Battery Attach Kit Smart Array P400 Battery Attach Kit NOTE This option kit contains a 24 battery cable and adhesive material for installing a battery into the following servers if a Smart Array P400 is integrated outside of the factory HP ProLiant ML310 G3 HP ProLiant DL320 G4 HP ProLiant ML350 G5 HP ProLiant DL380 G5 installations in a full size s...

Page 2: ...ng to fail but allows replacement of failing drives prior to actual failure For complete details consult the HP Support Center or refer to your HP Server documentation Key Features The SA P400 controller supports up to 18 drives The SA P400i supports up to 6 drives depending on the server implementation Seamless upgrades from past generations and upgrades to next generation HP high performance and...

Page 3: ...xpansion the SA P400 offers Up to 2TB of total storage with SATA HDD Up to 2 628TB of total storage with 18 x 146GB SFF SAS HDD Availability Provides increased server uptime by providing advanced storage functionality Online RAID level migration between any RAID level Online stripe size migration Online array expansion Online logical drive extension Online drive firmware upgrade Unlimited global o...

Page 4: ...re Recovery ROM This feature protects the user from a firmware image corruption by storing a redundant copy of the firmware image If the active firmware image becomes corrupt the controller will use the redundant firmware image and continue operating On Line Spares There is no limit to the number of spare drives that can be installed prior to drive failure If a failure occurs recovery begins with ...

Page 5: ...ssive generation of product and takes much of the guesswork out of troubleshooting field problems These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage Systems Insight Manager Powerful server and server options storage manager tool Monitors over 1200 system wide parameters Configuration Diagnostic Utilities HP...

Page 6: ...ility for all Smart Array controllers Runs offline for all supported Operating Systems and runs online for Windows and Linux QuickSpecs HP Smart Array P400 Controller Compatibility DA 12400 Worldwide QuickSpecs Version 5 10 3 2006 Page 6 ...

Page 7: ...o 24 hours x 7 days Duration Select duration of coverage for a period of 1 3 or 5 years Warranty upgrade options can come in the form of Care Packs which are sold at the HP System level this product attaches too HP Care Pack Information HP Care Pack is defined as an upgrade to the product warranty attribute available for a specific duration and hours of coverage Care Packs for this option is sold ...

Page 8: ...D 411276 B21 HP 160GB 1 5G SATA 7 2K NHP 3 5 HDD 411275 B21 HP 80GB 1 5G SATA 7 2K NHP 3 5 HDD 383410 B21 NOTE Go to the HP Hard Drive Compatibility table for complete drive compatibility information http www hp com products harddiskdrives Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and or loss of data NOTE There is a ...

Page 9: ...pport RAID 6 with ADG Advanced Data Guarding requires Battery Backed Write Cache Upgrade RAID 5 Distributed Data Guarding RAID 1 0 Striping Mirroring RAID 0 Striping Upgradeable Firmware Upgradeable Firmware with recovery ROM feature Copyright 2006 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows are registered trade...