C Physical and Environmental Specifications
provides temperature and airflow information for minimum, typical, and maximum
configurations for the HP 9000 rp4410 and rp4440 servers. It also lists the server and rack weights
and dimensions.
Table C-1 Physical and Environmental Specifications
Overall Server
(W x D x H)
Weight
Condition
Airflow, at
Maximum
Ambient degrees
C
1
Airflow, Nominal
Typical
Heat
Release
Pede-stal
Rack
Pede-stal
Rack
Server
Alone
180-264
VAC
W: 10.3 in
(26.1 cm)
D: 27.4 in
(69.5 cm)
H: 20.9 in
(53.0 cm)
W: 19 in
(48.2 cm)
D: 27.2 in
(69.0 cm)
H: 6.8 in
(17.3 cm)
115 lbs
(53 kg)
100 lbs
(45.4 kg)
88 lbs
(40 kg)
425
m3/hr
250
CFM
297
m3/hr
175 CFM
410 Watts
Min.
Config.
1368 Watts
Max.
Config.
1065 Watts
Typical
Config.
One CPU, one power supply, 1 GB DIMM, zero DVD,
one HDD, zero PCI cards, one core I/O.
Min./
Config.
Airflow cooling scheme (front to rear)
ASHRAE
Class 1
Four CPUs, two power supplies, 128 GB DIMM, one
DVD, two HDD, six PCI cards, two core I/O.
Max.
Config.
Two CPUs, two power supplies, 16 GM DIMM, one
DVD, two HDD, two PCI cards, one core I/O.
Typical
Config.
1
Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters.