HP R/T3000 G2 Quickspecs Download Page 3

Key Features

Key Features

Key Features

Key Features

New convertible design can be used as a 2U rack mountable UPS or as a standalone tower UPS
Increased power density with up to 3300VA / 3000 Watts (200-240V models)
Greater system uptime with support for up to two Extended Runtime Modules (ERM)
Easy configuration through enhanced front panel display
Enterprise-wide intelligent manageability with bundled power management software
Support for the HP UPS Network Module that extends the power management capabilities of the UPS
More efficient voltage regulation using digital signal processing technology
Ultimate long-term battery reliability with HP Enhanced Battery Management
Enhanced system flexibility with two independently controlled load segments
Support for Remote Emergency Power Off (REPO) circuitry
Easy serviceability through modular design
Hot-Swappable Batteries
Backed by a three year warranty with the first year including parts and labor. HP's Pre-Failure warranty, and a $250,000 load
protection guarantee

*

. (Certain restrictions and exclusions apply; 

*Load protection guarantee available in North America

only.

)

Optional upgrades include:

Extended Runtime Modules (ERMs)
Management Cards

New Convertible Design

New Convertible Design

New Convertible Design

New Convertible Design

The R/T3000 G2 can be used in a traditional rack mount environment or converted to a Tower UPS to
support powerful Tower servers even Tower Blade Servers such as the HP c3000 BladeSystem.

2U Power Packed Design

2U Power Packed Design

2U Power Packed Design

2U Power Packed Design Rated near unity at 3300VA / 3000W (200-240V models), the HP UPS R/T3000 G2 packs more power

in space-conserving rack-mount design, allowing you to support more critical equipment in your rack.

Increase System Uptime

Increase System Uptime

Increase System Uptime

Increase System Uptime
with Extended Runtime

with Extended Runtime

with Extended Runtime

with Extended Runtime
Modules

Modules

Modules

Modules

The Extended Runtime Modules are external battery modules that occupy 2U (3.5 inches) of rack space
each. The HP UPS R/T3000 G2 supports up to two Extended Runtime Modules (ERM), in either rack
mount or tower configuration, which extend your overall battery runtime.

Lower Cost of Ownership

Lower Cost of Ownership

Lower Cost of Ownership

Lower Cost of Ownership
with Innovative

with Innovative

with Innovative

with Innovative
Technology

Technology

Technology

Technology

The HP UPS R/T3000 G2 utilizes a new industry-leading technology that continually conditions and
regulates power without using the battery, thereby increasing the life of the battery. The output voltage is
automatically regulated, based on the connected load and the input voltage.

Investment Protection with

Investment Protection with

Investment Protection with

Investment Protection with
HP Enhanced Battery

HP Enhanced Battery

HP Enhanced Battery

HP Enhanced Battery
Management

Management

Management

Management

HP UPS R/T3000 G2 incorporates Enhanced Battery Management: an exclusive, patented technology
that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending
battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and
receive the best in the industry protection for your critical equipment.

Enhanced Flexibility

Enhanced Flexibility

Enhanced Flexibility

Enhanced Flexibility

The high voltage R/T3000 UPS include one PDU Extension Bar. The extension bar has seven C13 outlets
for powering equipment in the rack and attaches to the C19 outlets on the back of the UPS. The 6.5 foot
(2 meter) cord allows the extension bar to be mounted in many locations inside the rear of the rack.

QuickSpecs

HP R/T3000 G2 Uninterruptible Power System (UPS)

HP R/T3000 G2 Uninterruptible Power System (UPS)

HP R/T3000 G2 Uninterruptible Power System (UPS)

HP R/T3000 G2 Uninterruptible Power System (UPS)

Standard Features

DA - 14058   Worldwide — Version 2 — July 20, 2011

Page 3

Summary of Contents for R/T3000 G2

Page 1: ... In addition Extended Runtime Modules ERM are available to increase battery run time during a power outage ERMs can be used in both rack mount and tower configuration with the HP R T3000 G2UPS Robust and Flexible UPS management is provided by HP s New Power Protector UPS Management software R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration ...

Page 2: ...in Tower UPS configuration Models Models Models Models HP R T3000 G2 2U L530 Low Voltage NA JP Uninterruptible Power System AF466A HP R T3000 G2 2U L620 High Voltage NA JP Uninterruptible Power System AF467A HP R T3000 G2 2U Detachable Cord High Voltage INTL Uninterruptible Power System AF468A QuickSpecs HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS ...

Page 3: ...ded Runtime with Extended Runtime with Extended Runtime Modules Modules Modules Modules The Extended Runtime Modules are external battery modules that occupy 2U 3 5 inches of rack space each The HP UPS R T3000 G2 supports up to two Extended Runtime Modules ERM in either rack mount or tower configuration which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership Lower...

Page 4: ...LED and switch membrane integrated into the front panel with power controls and status and load indicators for easy visibility HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel 1 Dual function LED Self Test and load indicator 10 load 7 Power on button 2 Dual function LED Battery fault and Load Indicator 25 load 8 Power off button 3 Dual fun...

Page 5: ...wn connected server and server options HP Quality HP Quality HP Quality HP Quality HP s hardware qualification is the toughest in the industry Extensive evaluation testing product improvement and an unsurpassed warranty guarantee the highest level of system protection electrical performance product quality and compatibility Compatibility Compatibility Compatibility Compatibility Compatible with al...

Page 6: ... Related Services Related Services Related Services 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service Provides an IT manager with a team of support specialists who will quickly begin troubleshoo...

Page 7: ...he technical data sheet are not eligible for the defective media retention service feature option For more information For more information For more information For more information To learn more on services for HP ESSN Options please contact your HP sales representative or HP Authorized Channel Partner Or visit http www hp com services proliant or www hp com services bladesystem QuickSpecs HP R T...

Page 8: ...f the UPS from anywhere and at anytime via a standard web browser NOTE NOTE NOTE NOTE For more information on the UPS Network Module please see www hp com go hpunm Extended Runtime Module Extended Runtime Module Extended Runtime Module Extended Runtime Module ERM ERM ERM ERM The UPS R T3000 G2 supports up to two Extended Runtime Modules Each module is a 2U 3 5 inches rack mountable battery module ...

Page 9: ... Network Module AF465A HP Care Pack HP Care Pack HP Care Pack HP Care Pack HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS Related Options DA 14058 Worldwide Version 2 July 20 2011 ...

Page 10: ... has 7x C13 outlets and plugs into a C 19 on the rear of the UPS AF468A International 220 230 240 3300 3000 Detachable IEC C 20 inlet plug LS12 3x IEC C13 1x IEC C 19 LS23 3x IEC C13 1x IEC C 19 NOTE NOTE NOTE NOTE Includes one PDU Extension Bar Each Extension Bar has 7x C13 outlets and plugs into a C 19 on the rear of the UPS 1 Factory default setting 2 LS1 Load Segment 1 3 LS2 Load Segment 2 Kit...

Page 11: ...l model High Voltage NA JPN and Int l model High Voltage NA JPN and Int l model 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt Load Percent Load Percent Load Percent Load Percent Estimated battery runtime Estimated battery runtime Estimated battery runtime Estimated battery runtime Minutes Minutes Minutes Minutes With One Extended Runtime With One Extended Runtime With One Ext...

Page 12: ...ckup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Serial Ports Serial Ports Serial Ports Serial Ports Standard DB 9 and USB ports ships with communication cables Communications Communications Communications Communications Option Slot Option Slot Option Slot Option...

Page 13: ... for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2011 Hewlett Packard Development Company L P The information contained herein is subject t...

Reviews: