Unbuffered with ECC DIMMs (UDIMMs)
Unbuffered with ECC DIMMs (UDIMMs)
Unbuffered with ECC DIMMs (UDIMMs)
Unbuffered with ECC DIMMs (UDIMMs)
NOTE:
NOTE:
NOTE:
NOTE: Maximum 12 DIMMs supported per node
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
500668-B21
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
500670-B21
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
500672-B21
NOTE:
NOTE:
NOTE:
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed
memory configuration rules and guidelines, please use the Online DDR3 Memory
Configuration Tool:
www.hp.com/go/ddr3memory-configurator
.
NOTE:
NOTE:
NOTE:
NOTE: Kits described as LP include Low Power DIMMs. For more information on
ProLiant Energy Efficient Features, see:
www.hp.com/go/proliant-energy-efficient
NOTE:
NOTE:
NOTE:
NOTE: There is a maximum support limitation of 8 ranks per memory channel
(maximum of 2 quad rank DIMMs per channel)
NOTE:
NOTE:
NOTE:
NOTE: PC3L is a low voltage memory
Step 3: Choose Additional Factory Integratable Options
Step 3: Choose Additional Factory Integratable Options
Step 3: Choose Additional Factory Integratable Options
Step 3: Choose Additional Factory Integratable Options
HP Storage Controllers
HP Storage Controllers
HP Storage Controllers
HP Storage Controllers
HP Smart Array P212/256 BBWC 1-ports Int/1-ports Ext PCIe x8 FIO SAS Controller
NOTE:
NOTE:
NOTE:
NOTE: HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using
the P212 controller (574001-B21)
NOTE:
NOTE:
NOTE:
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491191-B21
HP Smart Array P410/ZM 2-ports Int PCIe x8 FIO SAS Controller
NOTE:
NOTE:
NOTE:
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using
the P410 controller (583997-B21)
462860-B21
HP Smart Array P410/256 BBWC 2-ports Int PCIe x8 FIO SAS Controller
NOTE:
NOTE:
NOTE:
NOTE: HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using
the P410 controller (583997-B21)
NOTE:
NOTE:
NOTE:
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491195-B21
HP Smart Array P411/256 BBWC 2-ports Ext PCIe x8 FIO SAS Controller
NOTE:
NOTE:
NOTE:
NOTE: HP z6000 BBWC HDWR KIT is required when adding BBWC (582653-B21)
491193-B21
HP Insight Software
HP Insight Software
HP Insight Software
HP Insight Software
HP Insight Control for Linux including 1yr 24x7 Support ML/DL Bundle 1 Server FIO
License
TC203A
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory Integration
NOTE:
NOTE:
NOTE:
NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below.
QuickSpecs
HP ProLiant SL170z Generation 6 (G6)
HP ProLiant SL170z Generation 6 (G6)
HP ProLiant SL170z Generation 6 (G6)
HP ProLiant SL170z Generation 6 (G6)
Configuration Information - Factory Integrated Models
DA - 13332 North America — Version 21 — November 14, 2011
Page 17