Removal and replacement procedures 65
o
Two SAS Expanders
15.
Close the PCI slot retainer cover.
16.
Install the fan cage.
17.
Install the air baffle.
18.
Install the access panel.
19.
Do one of the following:
o
If the server is in a tower configuration, return the server to an upright position.
o
If the server is in a rack configuration, slide the server into the rack.
20.
Connect each power cord to the server.
21.
Connect each power cord to the power source.
22.
Power up the server ("
23.
Do one of the following:
o
For tower models, install the tower bezel.
o
For rack models, install the security bezel.
8-LFF drive backplane
To remove the component:
1.
Back up all server data.
2.
Do one of the following:
o
For tower models, open and remove the tower bezel (on page
o
For rack models, if installed, remove the security bezel ("
Remove the security bezel (optional)
on page
3.
Power down the server (on page
4.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
5.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
Summary of Contents for ProLiant ML350 Gen9
Page 5: ...Contents 5 Index 123 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 18: ...Illustrated parts catalog 18 ...
Page 64: ...Removal and replacement procedures 64 LFF configuration SFF configuration ...
Page 91: ...Component identification 91 o Rack orientation 24 LFF drives o Tower orientation ...
Page 109: ...Cabling 109 Embedded SATA cabling LFF configuration SFF configuration ...
Page 112: ...Cabling 112 o SFF configuration o LFF configuration SAS Expander cabling One SAS Expander ...
Page 113: ...Cabling 113 o LFF configuration o SFF configuration ...