background image

1.
2.
3.
4.

NOTE:

 Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of

an HP approved configurator. Contact your local sales representative for additional information.

HP Unique Options

HP DL580 G7 PCI Express Kit

NOTE:

 Adds four PCI-E 2.0 x8, one PCI-E 2.0 x4 and one PCI-E 1.1 x4.

588137-B21

HP DL580 G7 PCI-X Combo Express Kit

NOTE:

 Adds two PCI-E 2.0 x16, one PCI-E 2.0 x4 and two PCI-X.

NOTE:

 Suggested Slot placement:

Slot 3 PCIe2 x 16 (16,8,4,2,1)
Slot 6 PCIe2 x 16 (16,8,4,2,1)
Slot 9 PCIe2 x 16 (8,4,2,1)*
Slot 11 PCIe2 x 16 (8,4,2,1)*
Slot 9 and 11 are physically a x16 slot but will operate electrically at x8

588139-B21

HP DL980 LP PCIe I/O Expansion Module

NOTE:

 Adds four PCI-E 2.0 x8, one PCI-E 2.0 x4.

AM434A

HP DL980 E7 Series CPU Installation Assembly

NOTE:

 Required for 8P configurations only. This part number will be used for Intel Xeon

E7-4800 and E7-2800 Series Processors.

AM450A

HP Processors

NOTE:

 Each processor kit contains four processors. 8P configurations require one HP

DL980 CPU Assembly (P/N: AM450A)

 

Ten-Core Processors

 

HP DL980 G7 Intel® Xeon® E7-2850 (2.0Ghz/10-core/24MB/130W) 4-processor Kit

NOTE:

 QPI speed is 6.4GT/s

650768-B21

HP DL980 G7 Intel® Xeon® E7-2860 (2.26GHz/10-core/24MB/130W) 4-processor Kit

NOTE:

 QPI speed is 6.4GT/s

650769-B21

HP DL980 G7 Intel® Xeon® E7-4870 (2.4GHz/10-core/30MB/130W) 4-processor Kit

NOTE:

 QPI speed is 6.4GT/s

650770-B21

Eight-Core Processors

 

HP DL980 G7 Intel® Xeon® E7-2830 (2.13GHz/8-core/24MB/105W) 4-processor Kit

NOTE:

 QPI speed is 6.4GT/s

650767-B21

Six-Core Processors

 

HP DL980 G7 Intel® Xeon® E7-4807 (1.86GHz/6-core/18MB/95W) 4-processor Kit

NOTE:

 QPI speed is 4.8GT/s

650766-B21

QuickSpecs

HP ProLiant DL980 Generation 7 (G7)

Core Options

DA - 13708   North America — Version 38 — September 23, 2013

Page  22

Summary of Contents for ProLiant DL980

Page 1: ...n positions shown lower four not shown 2 Mouse port 3 DVD drive bay 3 Serial port 4 Front panel LED display and Power button 4 Gigabit NIC port 5 Slide out System Insight Display 5 Gigabit NIC port 6 Two front accessible USB 2 0 ports 6 Gigabit NIC port 7 One front video port 7 Gigabit NIC port 8 Quick release lever for fast server access 8 Video port 9 Upper and lower front accessible processor a...

Page 2: ...3TB G2 Multi Level Cell PCIe ioDrive2 IO Accelerator Support for HP ProLiant DL980 331i SPI Board based on integrated 331i quad port 1GbE networking controller Support for HP ProLiant NC375i SPI Board based on integrated NC375i quad port 1GbE networking controller QuickSpecs HP ProLiant DL980 Generation 7 G7 Overview DA 13708 North America Version 38 September 23 2013 Page 2 ...

Page 3: ... E7 4870 Processor only 24MB 1 x 24MB Level 3 cache NOTE For E7 2830 E7 2850 and E7 2860 18MB 1 x 18MB Level 3 cache NOTE For E7 4807 Processor only Chipset Industry Standard Intel 7500 Chipset Hewlett Packard DL980 G7 Node Controller NOTE Up to three Industry Standard Intel 7500 Chipsets with six high speed interconnects up to 6 4GT s NOTE For more information regarding Intel chipsets please see ...

Page 4: ...rd Expansion Slot Technology Width Connector Width Bus Number Form Factor Notes 1 N A N A N A N A N A N A 2 N A N A N A N A N A N A 3 N A N A N A N A N A N A 4 N A N A N A N A N A N A 5 N A N A N A N A N A N A 6 N A N A N A N A N A N A 7 PCI Express Gen2 x4 x8 0x05 FH FL 8 PCI Express Gen2 x4 x8 0x08 FH FL 9 PCI Express Gen2 x8 x16 0x0B FH FL 10 PCI Express Gen2 x4 x8 0x0E FH FL 11 PCI Express Gen...

Page 5: ...s Gen2 x8 x16 0x11 FH FL Default bus assignment Inserting cards with PCI bridges may alter the actual bus assignment number Slots are enumerated differently based on OS MS OS s enumerate from lowest to highest Device ID by bus starting with the lowest bus FL Full length FH Full height LP low profile Expansion Slots with Standard PCI e option I O Expander Expansion Slot Technology Width Connector W...

Page 6: ...Full length FH Full height LP low profile Expansion Slots with Low Profile I O expander PCI e option Expansion Slot Technology Width Connector Width Bus Number Form Factor Notes 7 PCI Express Gen2 x4 x8 0x05 FH FL 8 PCI Express Gen2 x4 x8 0x08 FH FL 9 PCI Express Gen2 x8 x16 0x0B FH FL 10 PCI Express Gen2 x4 x8 0x0E FH FL 11 PCI Express Gen2 x8 x16 0x11 FH FL 12 PCI Express Gen2 x8 x16 0x71 LP 13 ...

Page 7: ... 1 FH FL 100MHz 2 PCI X 64 bit N A 0x52 Device 2 FH FL 100MHz 3 PCI Express Gen2 x16 x16 0x56 FH FL 4 PCI Express Gen2 x4 x8 0x59 FH FL 5 N A N A N A N A N A N A 6 PCI Express Gen2 x16 x16 0x5C FH FL 7 PCI Express Gen2 x4 x8 0x05 FH FL 8 PCI Express Gen2 x4 x8 0x08 FH FL 9 PCI Express Gen2 x8 x16 0x0B FH FL 10 PCI Express Gen2 x4 x8 0x0E FH FL 11 PCI Express Gen2 x8 x16 0x11 FH FL 12 PCI Express G...

Page 8: ... 2 PCI Express Gen2 x8 x16 0x54 FH FL 3 PCI Express Gen2 x8 x16 0x57 FH FL 4 PCI Express Gen2 x4 x8 0x5A FH FL 5 PCI Express Gen2 x8 x16 0x5D FH FL 6 PCI Express Gen2 x8 x16 0x60 FH FL 7 PCI Express Gen2 x4 x8 0x05 FH FL 8 PCI Express Gen2 x4 x8 0x08 FH FL 9 PCI Express Gen2 x8 x16 0x0B FH FL 10 PCI Express Gen2 x4 x8 0x0E FH FL 11 PCI Express Gen2 x8 x16 0x11 FH FL 12 PCI Express Gen2 x8 x16 0xA1...

Page 9: ...C increases cache data retention capabilities from two days of existing battery backed write cache BBWC to infinite data retention Standard on 4P Models optional on factory integrated models Transportable data protection Increases overall controller performance Internal Storage Devices Diskette Drive None Optical Drive Slimline DVD RW Drive standard Hard Drives None ship standard Hard Disk Drive B...

Page 10: ... supplies there is no power redundancy Eight power supplies are required for power redundancy The level of redundancy will be reported during the system power on System Fans 8 Hot plug redundant fans ship standard Required Cabling For required cabling information refer to the HP Web site at www hp com servers dl980 Operating Systems and Virtualization Software Support for ProLiant Servers Microsof...

Page 11: ...smartstart NOTE In an effort to support reducing our environmental impact the HP Insight Foundation Suite for ProLiant media will be available as a selectable option for this server at time of order of a CTO SKU This will allow customers to order the number of media kits that best meet their needs and eliminate receiving unnecessary duplicate media HP Integrated Lights Out iLO HP Integrated Lights...

Page 12: ...r three years from date of purchase Support for software and initial setup is available for 90 days from date of purchase Enhancements to warranty services are available through HP Care Pack services or customized service agreements Hard drives have either a one year or three year warranty refer to the specific hard drive QuickSpecs for details NOTE Server Warranty includes 3 Year Parts 3 Year Lab...

Page 13: ...asks by as much as 40 percent As a powerfully integrated by design toolkit to accelerate complex technology projects and simplify daily operations that ultimately enable IT Staff personnel to dynamically keep pace with the organizations changing business requirements It enables them to plan capacity and power continuously balance across physical and virtual resources and ensure cost effective high...

Page 14: ...cheduler the HP MPI parallelization library Also included are the HP Unified Parallel C compiler and the HP Shmem library as well as the execution environments for the libraries and compiler HP HPC Linux Value Pack Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration customization integration and deployment services for HP servers and storage products Customers...

Page 15: ...ist you in bringing your new hardware into operation in a timely and professional manner http h20195 www2 hp com V2 GetPDF aspx 5981 9356EN 3 Year HP Proactive Care 6 Hour Call to Repair Service This service has been specifically designed to meet the needs of customers who run their business processes on HP x86 Servers Platforms This service combines reactive and proactive services to help custome...

Page 16: ...in a timely and professional manner http h20195 www2 hp com V2 GetPDF aspx 5981 9356EN 3 Year HP Collaborative Support 24x7 Provides full hardware and basic SW support for HP Proliant DL980 servers along with diagnosis and advice on problem resolution for industry standard software products from major independent software vendors ISVs This service provides single point of contact for support call ...

Page 17: ...al System services please contact your HP sales representative or HP Authorized Channel Partner Or visit http www hp com services bcs QuickSpecs HP ProLiant DL980 Generation 7 G7 Service and Support DA 13708 North America Version 38 September 23 2013 Page 17 ...

Page 18: ... Cache Memory 30MB 1 x 30MB Level 3 cache Memory 256GB 32 x 8GB PC3 10600R Registered DIMMs DDR3 Network Controller HP NC375i Integrated Quad Port Gigabit Server Adapter Storage Controller HP Smart Array P410i Controller with 512MB FBWC Hard Drives None ship standard Internal Storage 7 2TB max with optional 900GB SAS hard drives Optical Drive Slimline DVD RW Drive standard Power Supply Eight 1200W...

Page 19: ...pport with next business day response HP ProLiant DL980 G7 E7 2830 2 13GHz 8 Core 4p Server AM449A Processor s 4 Intel Xeon E7 2830 2 13GHz 8 core 24MB 105W Processors Cache Memory 24MB 1 x 24MB Level 3 cache Memory 128GB 16 x 8GB PC3 10600R Registered DIMMs DDR3 Network Controller HP NC375i Integrated Quad Port Gigabit Server Adapter Storage Controller HP Smart Array P410i Controller with 512MB F...

Page 20: ...integrated on system board Rack form factor 8U Step 2 Choose Required Options only one of the following from each list unless otherwise noted HP Processors NOTE Each processor kit contains four processors NOTE If eight processors are desired select one xxxxxx L21 and one xxxxxx B21 Additionally one HP DL980 CPU Assembly P N AM450A for Intel Xeon E7 4800 and E7 2800 Series Processors will be requir...

Page 21: ...mily only A0R59A HP DL980 32GB 1x32GB Quad Rank x4 PC3L 8500R 7 DDR3 1333 Registered CAS 9 Low Power Memory Kit NOTE For Intel Xeon E7 Family only A0R61A HP DL980G7 E7 Memory Cartridge A0R60A HP Optical Drives HP Slim 12 7mm SATA DVD ROM Optical Drive 481041 B21 HP Slim 12 7mm SATA DVD RW Optical Drive 481043 B21 Step 3 Choose Additional Factory Integratable Options only one of the following from ...

Page 22: ...lation Assembly NOTE Required for 8P configurations only This part number will be used for Intel Xeon E7 4800 and E7 2800 Series Processors AM450A HP Processors NOTE Each processor kit contains four processors 8P configurations require one HP DL980 CPU Assembly P N AM450A Ten Core Processors HP DL980 G7 Intel Xeon E7 2850 2 0Ghz 10 core 24MB 130W 4 processor Kit NOTE QPI speed is 6 4GT s 650768 B2...

Page 23: ... P N AM450A HP Optical Drives HP Slim 12 7mm SATA DVD ROM Optical Drive 481041 B21 HP Slim 12 7mm SATA DVD RW Optical Drive 481043 B21 HP Hard Drives NOTE The components of a storage subsystem e g the drive the HBA controller firmware and the server backplane should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components NOTE...

Page 24: ...rmance 3yr Warranty Solid State Drive 632492 B21 HP 400GB 6G SAS MLC SFF 2 5 inch Enterprise Mainstream 3yr Warranty Solid State Drive 632504 B21 HP 200GB 6G SAS MLC SFF 2 5 inch Enterprise Mainstream 3yr Warranty Solid State Drive 632502 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 14038_na 14038_na html Wor...

Page 25: ...ort Server Adapter 593717 B21 HP NC524SFP Dual Port 10GbE Module 489892 B21 HP NC550SFP Dual Port 10GbE Server Adapter 581201 B21 HP NC552SFP 10Gb 2 port Ethernet Server Adapter 614203 B21 HP Ethernet 10Gb 2 Port 530SFP Adapter 652503 B21 HP Ethernet 10Gb 2 Port 560SFP Adapter 665249 B21 HP Ethernet 10Gb 2 port 530T Adapter 656596 B21 NOTE The DL980 G7 can support up to Either four NC523SFP or fou...

Page 26: ... 2 1 Slot 9 and 11 are physically a x16 slot but will operate electrically at x8 588139 B21 HP DL580 G7 PCI Express Kit NOTE Adds four PCI E 2 0 x8 one PCI E 2 0 x4 and one PCI E 1 1 x4 588137 B21 Low Profile PCI Express I O Expansion Kit NOTE Adds four PCI E 2 0 x8 one PCI E 2 0 x4 AM434A HP Power Supplies NOTE Prior to making a power supply selection it is highly recommended that the HP Power Ad...

Page 27: ...onic License TC213AAE HP Insight Control for Linux including 1yr 24x7 Support Single Server License TC209A HP Insight Control for Linux Media Kit TC208A NOTE Licenses ship without media The Media Kit for Insight Control for Linux can be ordered separately or can be downloaded at http www hp com go ic linux click on Download button NOTE Customer will receive a license entitlement certificate which ...

Page 28: ...titlement certificate must be redeemed online in order to obtain a license key QL803A HP Cluster Management Utility License and Media NOTE Order a minimum of one license per cluster to purchase media including software and documentation which will be delivered to the customer and also licenses CMU management No license key is delivered or required 433257 B21 NOTE For additional license kits please...

Page 29: ...file PCI bracket is included for use in low profile slots 600279 B21 HP 320GB Single Level Cell PCIe ioDrive Duo for ProLiant Servers 600281 B21 HP 640GB Multi Level Cell PCIe ioDrive Duo for ProLiant Servers 600282 B21 HP 1 28TB Multi Level Cell PCIe IO Accelerator 641027 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products qu...

Page 30: ...s Ext PCIe x8 SAS Controller 487204 B21 Optional Upgrades NOTE Maximum of two battery or FBWC kits for Smart Array Controllers can be installed in upper full height full length FH FL I O slot area Maximum of one battery or FBWC kit for Smart Array Controller can be installed in lower low profile LP I O slot area HP 650 mAh P Series Battery NOTE Supported on HP Smart Array P212 Controller and HP Sm...

Page 31: ... For installation into 1U SAS rack kit AE459B or 3U SAS rack kit AG576B No peripheral bay available for installation into the server Connection using HP P212 Smart Array Controller SAS 462828 B21 recommended EH847A HP LTO 4 Ultrium 1760 SAS Internal WW Tape Drive NOTE For installation into 1U SAS rack kit AE459B or 3U SAS rack kit AG576B No peripheral bay available for installation into the server...

Page 32: ...le Disk Backup Systems USB HP StorageWorks RDX500 Internal Removable Disk Backup System NOTE For installation into 1U USB Rack Mount Kit A8007A No peripheral bay available for drive installation into the server 500GB of disk capacity per data cartridge AJ934A HP Storage Options Storage Fibre Channel HBA NOTE The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux For d...

Page 33: ...1000E or CN1100E or CN1000Q is supported BS668A HP Disk Storage Systems MSA SAN Storage Arrays HP Modular Smart Array 50 Enclosure 364430 B21 NOTE Please see the QuickSpecs for additional options and configuration information at http h18000 www1 hp com products quickspecs 12245_na 12245_na html Worldwide Disk Enclosures HP D2600 Disk Enclosure AJ940A HP D2700 Disk Enclosure AJ941A NOTE Please see ...

Page 34: ...wer System UPS HP R5KVA 3U IEC309 32A High Voltage INTL Uninterruptible Power System AF461A HP R5KVA 3U L630 High Voltage NA JP Uninterruptible Power System AF460A NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 14109_na 14109_na html Worldwide R7000 Uninterruptible Power System UPS HP R7KVA 4U 50A High Voltage NA JP Uninterruptible Power Syste...

Page 35: ... including shorter jumper cables and country specific power cords http h18000 www1 hp com products quickspecs 11041_na 11041_na html Worldwide NOTE For additional information on HP Power Distribution Units including accessories please go to www hp com go pdu NOTE Please see the UPS and PDU cable matrix s on the HP Power Protection and Management page Under Power Cords click on the HP Power Cord Ma...

Page 36: ...ding Compaq HP 7000 9000 10000 G2 and HP series with an adjustment range of 24 36 The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management HP Rack Options HP KVM Switch Options HP 2x1Ex16 KVM IP Console Switch G2 with Virtual Media CAC Software AF621A HP 4x1Ex32 KVM IP Console Switch G2 with Virtual Media CAC Software AF622A HP 0x2x16 KVM ...

Page 37: ... HP Care Pack Services Hardware Services On site Service HP 3 year 4 hour 13x5 ProLiant DL980 Hardware Support UV301E HP 3 year 4 hour 24x7 ProLiant DL980 Hardware Support UV298E 6 Hour Call to Repair On site Service 7 Day x 24 Hour Coverage 3 Years U S Part Number HP 3 year 6 hour 24x7 Call To Repair ProLiant DL980 Hardware Support UV292E Installation Start up Services HP Install ProLiant DL980 H...

Page 38: ...y HP recommends using identical part numbered DIMMs throughout when possible DIMM Quads MUST be populated in sequence by letter designation Install DIMMs 1A and 8A on each cartridge first followed by DIMMs 3B and 6B on each cartridge then DIMMs 2C and 7C and finally DIMMs 4D and 5D last Maximum performance is achieved by balancing DIMM Quads by letter groupings across all memory cartridges All 1A ...

Page 39: ... speeds of 1066 or 1333 running at 1066 are supported UDIMMs are not supported The following memory options are available from HP HP Memory Registered DIMMs RDIMMs HP 2GB 1x2GB Dual Rank x8 PC3 10600 DDR3 1333 Registered CAS 9 Memory Kit 500656 B21 HP 4GB 1x4GB Single Rank x4 PC3 10600 DDR3 1333 Registered CAS 9 Memory Kit 593339 B21 HP DL980 4GB 1x4GB Single Rank x4 PC3L 10600 DDR3 1333 Registere...

Page 40: ... down to an acceptable level for all components NOTE Hard drives have either a one year or three year warranty refer to the specific hard drive QuickSpecs for details SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives Quantity Supported Position Supported Controller 900GB 6G SAS 10K 600GB 6G SAS 10K 450GB 6G SAS 10K 300GB 6G SAS 10K 300GB 6G SAS 15K 146GB 6G SAS 15K 72GB 6G SAS 15K Up to 8 1 8 HP Sma...

Page 41: ...nal HP Smart Array P411 256 MB Controller HP Smart Array P411 512 MB BBWC Controller HP Smart Array P411 1G FBWC Controller HP Smart Array P812 Controller D2700 Disk Enclosure Up to 2 External HP Smart Array P212 256 MB Controller Up to 4 External HP Smart Array P411 256 MB Controller HP Smart Array P411 512 MB BBWC Controller HP Smart Array P411 1G FBWC Controller HP Smart Array P812 Controller M...

Page 42: ...L2024 MSL4048 MSL8096 MSL6000 External HP U320e SCSI Dual Channel Host Bus Adapter AH627A HP SAS Tape Autoloaders and Libraries 1 8 G2 Autoloader MSL2024 MSL4048 MSL8096 External HP Smart Array P212 ZM 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462828 B21 HP USB RDX Removable Disk Backup System RDX160 RDX320 RDX500 RDX750 External USB 2 0 port N A HP D2D Backup Systems iSCSI D2D2500i D2D4000i ...

Page 43: ...D2D4000fc External Direct server attach is not supported requires connection via SAN fabric See http www hp com storage SPOCK QuickSpecs HP ProLiant DL980 Generation 7 G7 Storage DA 13708 North America Version 38 September 23 2013 Page 43 ...

Page 44: ...ated VA Volt Amp 1345 1345 1345 1345 1345 Efficiency 93 93 93 93 93 Power Factor 0 97 Leakage Current mA 0 83 0 87 0 92 0 96 1 00 Maximum Inrush Current A peak 30 Maximum Inrush Current duration mS 10 Maximum British Thermal Unit Rating BTU Hr 4403 4403 4403 4403 4403 To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL www hp com go...

Page 45: ... per power supply Rated Steady State Power 1200W 200 240VAC Maximum Peak Power 1440W 200 240VAC System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the t...

Page 46: ...te compliance logos and statements Integrated Lights Out 3 Standard integrated on system board Architecture PCI Express based health and remote management ASIC Processor PCI Express RISC processor core running at 250MHz Upgradeability Option firmware upgradeable via flash ROM Video Support 1600 x 1200 DVR max resolution Interfaces One Ethernet Sideband connection 10 100 1000 Mb s One Ethernet netw...

Page 47: ...ace 6Gb s SAS Serial Attached SCSI SAS Connectors 2 internal mini SAS x8 wide port connectors Cache Memory Speed DDR2 800MHz with 40 or 72 bit wide bus provides up to 4 2GB s maximum bandwidth Server Interface x4 PCIe provides 2GB s maximum bandwidth SAS Speed x8 6G SAS provides 4 8GB s maximum bandwidth Cache Memory 72 bit 512MB or 1GB Flash backed write cache transportable with flash upgrade Log...

Page 48: ...ant DL980 331i SPI Board Network Interface 10Base T 100Base TX 1000Base TX Compatibility IEEE 802 3 10Base T IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX IEEE dynamic 802 3ad 1000Base TX IEEE 802 3x IEEE 802 3az IEEE 1588 IEEE 802 1as IEEE 802 1Q 100Base TX Data Transfer Method Four lane x4 PCI Express compatible with x4 x8 and x16 PCI Express slots Controller Broadcom BCM5719 chipset Network Tr...

Page 49: ...other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2013 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation Unix is a registered trademark of The Open Group Intel the Intel logo Xeon and Xeon Inside are tra...

Reviews: