Removal and replacement procedures 58
o
3-slot riser cage
o
2-slot riser cage
To replace the component, reverse the removal procedure.
If you are not replacing the enablement board, install the screw back into the PCIe riser cage before
installing the PCIe riser cage back into the server.
Heatsink
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
CAUTION:
To avoid thermal shutdown, all fans must be installed in a dual processor
configuration.
To remove the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page