Removal and replacement procedures 53
5.
Power up the recovery server. A 1759 POST message is displayed, stating that valid data was flushed
from the cache. This data is now stored on the drives in the recovery server. You can now transfer the
drives (and controller, if one was used) to another server.
Flash-backed write cache procedures
Two types of procedures are provided for the FBWC option:
•
Removal and replacement of failed components:
o
Removing the cache module
o
Removing the capacitor pack
•
Recovery of cached data from a failed server ("
Recovering data from the battery-backed write cache
CAUTION:
Do not detach the cable that connects the battery pack or capacitor pack to the cache
module. Detaching the cable causes any unsaved data in the cache module to be lost.
Flash-backed write cache module
To remove the component:
CAUTION:
Do not use this controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache
module to a different controller module, because you can lose data.
1.
Back up all data.
2.
Close all applications.
3.
Power down the server (on page
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
4.
Extend the server from the rack (on page
5.
Remove the access panel ("
" on page
6.
Remove the PCI riser cage ("
" on page
7.
If the existing cache module is connected to a capacitor pack, observe the FBWC module LEDs (on
page
o
If the amber LED is flashing, data is trapped in the cache. Restore system power, and restart this
procedure from step 1.
o
If the amber LED is not illuminated, remove the controller from the server, and then continue with the
next step.
Summary of Contents for ProLiant DL380 G7
Page 5: ...Contents 5 Index 110 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 16: ...Customer self repair 16 ...
Page 20: ...Illustrated parts catalog 20 System components ...
Page 82: ...Cabling 82 Cabling SAS hard drive cabling Optical drive cabling ...
Page 83: ...Cabling 83 BBWC battery cabling FBWC capacitor pack cabling ...